Page 189 - Surge-Protection-E_0.pdf
P. 189

Compact SPDs – DIN Rail Mounted


           DEHNconnect SD2
           • Terminal block with integrated surge protection
               – For protecting measuring and control circuits and bus systems
               – Maximum impulse current carrying capability Imax up to
              20 kA (8/20 µs)
               – Low voltage protection level, capable of protecting terminal
              equipment
           • Modular disconnection function
               – Disconnection module for disconnecting the signal circuit for
              maintenance work
               – Module fixing and mechanical ejector
               – Module in "parked" position after disconnection
           • Space-saving and function-optimised design
               – Terminal block with integrated surge protection (width of 6 mm)
               – Fast conductor connection without tools thanks to direct plug-in
              technology
                                                                                                                      Compact SPDs –   DIN Rail Mounted
               – Can be used with jumper bar (accessory)




                                                                Application example: DEHNconnect for protecting the I/O of PLC interfaces.


           The surge arresters of the DEHNconnect SD2 series are designed as   Conductors are connected via a vibration-proof spring-loaded connection
           space-saving terminal blocks with a width of 6 mm. These terminal blocks   system. Stripped solid conductors and flexible conductors with wire end
           with integrated surge protection have a modular disconnection function   ferrule can be easily and quickly inserted into the relevant conductor ter-
           that allows them to interrupt the signal circuit for maintenance work. An   minal without tools. For rewiring, the conductor is removed from the
           integrated module ejector disconnects the signal circuit from the terminal   clamping point and clamped into a new conductor terminal.
           equipment. The disconnection module does not have to be removed, but   To reduce wiring, jumper bars can be inserted on the protected side of the
           remains in a "parked" position in the module slot.   surge arrester, thus quickly connecting signal circuits.
           Different types of arrester are available to protect two single lines sharing   The arresters are ideally suited for use in industrial environments at infor-
           a common reference potential (unbalanced interfaces) or an unearthed   mation technology signal interfaces of automation, measuring and control
           pair (balanced interface). Arresters with a high cut-off frequency (HF) can   as well as bus systems.
           be used for balanced bus interfaces with high data rates (e.g. Profibus,
           RS485).










           Disconnection module with ejector –   Marking of the protected side – mini-  Terminals  with  direct-plug-in  tech-  Slots  for  jumper  bars  –  for  quickly
           for disconnecting the signal circuits.  mises wiring errors.  nology – fast and vibration-proof   connecting signal circuits.
                                                                connection.































           Valid as of August 1, 2020                        You will find detailed product information on our website   185
   184   185   186   187   188   189   190   191   192   193   194