Page 159 - V16 Catalogue Final
P. 159

SURGE PROTECTION - 1000V




                                   SURGE ARRESTOR (DEHN)
        Features:                          In              Max.
        - Uc ≤ 1000V a.c. r.m.s  (IEC 61643-11).  (8/20μsec)   continuous   TOV (U )         Type of
        - Compact single-pole surge arrester   Nominal   Max.   operaing  Voltage   T  Operating  remote
           specifically designed for high system   Imax  Discharge  overcurrent  voltage  protection  With   Safe   state/fault  signalling
           voltages.               (8/20µsec) current  protection  (a.c.) (U ) c  level (U ) p  stand  Failure  indication  contact Part No.
        - High discharge capacity due to  SPD according to EN 61643-11 / IEC 61643-11: Type 2 / Class II
           heavy-duty zinc oxide varistor.  30 kA  15 kA  100 A aM  1000 V   ≤4.2 kV  1205V  1580V /  Green /   -  DG1000
        - High reliability due to “Thermo                  (50/60Hz)      / 5 sec. 120 min.  Red
           Dynamic Control” disconnector.













                 DG1000



        Features:                          In              Max.
        - Uc ≤ 1000V a.c. r.m.s  (IEC 61643-11).  (8/20μsec)   continuous                    Type of
        - Compact single-pole surge arrester   Nominal   Max.   operaing  Voltage   TOV (U ) T  Operating  remote
           specifically designed for high system   Imax  Discharge  overcurrent  voltage  protection   state/fault  signalling
           voltages.               (8/20µsec) current  protection  (a.c.) (U ) c  level (U ) p  With stand  indication  contact Part No.
        - High discharge capacity due to  SPD according to EN 61643-11 / IEC 61643-11: Type 2 / Class II
           heavy-duty zinc oxide varistor.
                                                                                              C/O
                                                                          1550V  1320V /  Green /
        - High reliability due to “Thermo  40 kA  15 kA  100 A gG  1000 V   ≤5 kV  / 5 sec. 120 min.  Red  contact  DGSEH1000VAFM
                                                           (50/60Hz)
           Dynamic Control” disconnector.
                                                                                                                   SURGE
                                                                                                                  PROTECTION







              DGSEH1000VAFM





                                   ACCESSORIES
                                    Description                                                    Part No.
                                    Earthing Clip 3 Pole DG1000FM (x3)                             EBDG100013
                                    Earthing Clip 4 Pole DG1000FM (x4)                             EB149
                                    Earthing Clip 3 Pole DGSEH1000VAFM (x3)                        EB131.5
                EBDG100013
                                    Earthing Clip 4 Pole DGSEH1000VAFM (x4)                        B141.5






                 EB131.5






        Phone: 1300 556 601                            www.ipd.com.au                                V16-PD-SP-R02  151
   154   155   156   157   158   159   160   161   162   163   164