DIGIWARE PLUG AND PLAY AC METERING SYSTEM
           CURRENT MODULES


                                               AC CURRENT MEASUREMENT MODULES
          Features:                             Description                 Current Sensor Inputs    Part No.
          - Global accuracy Class 0.5 (meter + ct) to IEC 61557-12.
          - Meter accuracy Class 0.2.           Metering Application
          - RJ12 connections to current sensors.  I-30 current module             3                    48290110
          - Plug & Play, RJ45 connection.       I-31 current module               3                   48290111
          - Multi-circuit measurement.          I-60 current module               6                  48290112
          - Auto configuration.                 I-61 current module               6                  48290113
          - Flexible, solid or split-core current sensors.
          - DIN rail mount measurement modules.  Monitoring Application
                                                  I-33 current module             3                    48290128
                                                Analysis Application
                                                I-35 current module               3                  48290130
                                                I-43 current module               4                  48290129
                                                I-45 current module               4                  48290131
                                               - Up to 32 current modules can be used in a Digiware system.
                                               - Measure: Basic.              Monitor: Intermediate.              Analyse: Advanced.




               I-30 / I-31     I-60 / I-61     AC CURRENT MEASUREMENT MODULE SELECTION CHART
                                                                                 Current measurement modules
                                               Application             Metering  Monitoring  Analysis    Metering







                                               DIRIS Digiware I      I-30  I-31  I-33  I-35  I-43  I-45  I-60  I-61
                                               Number of current inputs
                                                                      3    3     3     3     4     4     6    6
                                               Metering
                        I-33                    +/- kWh, +/- kvarh, kVAh  *  *   *     *     *     *     *    *
                                                Load curves                *           *           *          *
                                                Multi-tarif                *           *           *          *
                                               Multi-measurement
                                                I1, I2, I3, In, ∑P, ∑Q, ∑S, ∑PF  *  *  *  *  *     *     *    *
                                                P, Q, S, PF per phase            *     *     *     *
                                                Predictive power                       *           *
                                                Current unbalance (Inba, Idir, Iinv,   *           *
                                                Ihom, Inb)
                                                Phi, cos Phi, tan Phi                  *           *
                                               Quality
                                                THDi1, THDi2, THDi3,THDin        *     *     *     *
                                                Individual harmonics I (up to level 63)  *         *
                 I-35            I-45           Overcurrents                           *           *
                                               Alarms
                                                On threshold                           *           *
                                                Inputs/Outputs                              2/2   2/2
                                               History of average values
                                                45 days (max                           *           *
                                               Format
                                                Width/number of modules  18mm/1 18mm/1 18mm/1  18mm/1 27mm/1.5 27mm/1.5 36mm/2 36mm/2
                                               - I-30, I-31, I-33 and I-35 are 1 DIN module wide.
                                               - I-45 is 1.5 DIN modules wide.
                                               - I-60 and I61 are 2 DIN modules wide.



    310   V16-PM-R04                                    www.ipd.com.au                             Phone: 1300 556 601