MANUAL MOTOR STARTER - ACCESSORIES




                                             THREE-PHASE BUSBARS
                                                           Rated
                                                           operational   Number of   Number of
        Features:                             Suitable for  current      MMS       lateral aux.    Part No.
        - Quick and safe connection.                                                               PS1-2-0-65
        - Rated 65A, 100A and 125A.                        65            2         0
        - Fork type for PS1 and Pin type for PS2.          65            3         0               PS1-3-0-65
                                                           65            4         0               PS1-4-0-65
                                                           65            5         0               PS1-5-0-65      MOTOR
                                                           65            2         1               PS1-2-1-65     BREAKERS
                                              MS116        65            3         1               PS1-3-1-65
                                              MS132        65            4         1               PS1-4-1-65
                   PS1-2-0-65                              65            5         1               PS1-5-1-65
                                                           65            2         2               PS1-2-2-65
                                                           65            3         2               PS1-3-2-65
                                                           65            4         2               PS1-4-2-65
                                                           65            5         2               PS1-5-2-65
                                                           100           3         0               PS1-3-0-100
                                                           100           4         0               PS1-4-0-100
                                                           100           5         0               PS1-5-0-100
                                              MS116
                   PS1-3-0-100                MS132        100           3         1               PS1-3-1-100
                                                           100           4         1               PS1-4-1-100
                                                           100           5         1               PS1-5-1-100
                                                           100           3         2               PS1-3-2-100
                                                           125           2         0               PS2-2-0-125
                                                           125           3         0               PS2-3-0-125
                                                           125           4         0               PS2-4-0-125
                                              MS165
                                                           125           2         2               PS2-2-2-125
         PS2-2-0-125        PS2-3-0-125                    125           3         2               PS2-3-2-125
                                                           125           4         2               PS2-4-2-125
                                             - PS1 Busbars are only suited for screw versions.







                                             THREE-PHASE FEEDER TERMINALS

                                                            Rated operational  Cross
                                              Suitable for  current (A)  section (mm²)  Mounting form  Part No.
                                                           65            25        Flat            S1-M1-25
                                              MS116        65            25        High            S1-M2-25
                                              MS132        65            25        IEC             S1-M3-25
               S1-M3-35       S1-M2-25        MS165
                                                           100           35        IEC             S1-M3-35