Page 388 - V16 Catalogue Final
P. 388

ENCLOSED DOL STARTERS - DRAF
           RELIABLE AND EASY TO INSTALL MOTOR STARTING


                                                               IEC - AC-3 Rated operational power
          Features:                             220 V                               Max. current
          - Improve installation efficiency.    230 V       380 V                   θ ≤ 40 °C
          - Reliable in harsh condition.        240 V       400 V       500 V       Ue=400 V         Part No.
                                                            (kW)
                                                (kW)
                                                                        (kW)
                                                                                    (A)
          - Continuous operation.
                                                2.2         4           5.5         9                DRAF09-1*
                                                3           5.5         7.5         12               DRAF12-1*
                                                4           7.5         9           18               DRAF16-1*
                                               * To complete Part Number, add the required voltage code:
                                                Code                   1S            3N            4P
                                                Control Voltage        24…60V        100...250V    250...500V
                                                Uc min...Uc max. (50/60 Hz)



                                                4 cable entries          AF 3-pole contactor with
                                                                         holding contact

                                                                                       "I" ON  button
                                                Start contact
                                                block








                                                1 PE and
                                                1 neutral terminal

                                                TF42 thermal                          "0" OFF/RESET
                                                overload relay                        button

                                               TF42 thermal overload relays (to be ordered separately)



                                               DIMENSIONS

                                                                           131.5  5.18"
                                                                          126.5  4.98"
                                                                        60 2.36"
                                                         107 4.22"      8 .32"






                                                                 230 9.06"

                                                 Ø 22.3 .88"





                                                          DRAF09, DRAF12, DRAF16


                                                Cable inlets (Enclosure top)  Cable outlet (Enclosure bottom)
                                                2 x ø 20 mm              2 x ø 20 mm
                                                2 x ø 0.79"              2 x ø 0.79"

    380   V16-IC-MB-R02                                 www.ipd.com.au                             Phone: 1300 556 601