Page 414 - V16 Catalogue Final
P. 414

TIME SWITCHES
           ANALOGUE


                                                Battery   Minimum                        Supply
          Features:                             back-up  switching time  Function  Contacts  voltage  Part No.
          - Simple programming.                 Modular DIN Rail Mount
          - Manual override.
          - Backlit display.                    no       15 min.     Daily  1 x N/O, 16 Amps  230V AC  UNO-D-230VAC
          - Display of operating schedule and relay      100 hrs  15 min.  Daily  1 x N/O, 16 Amps  230VAC  UNO-QRD-230VAC
             status.                            100 hrs  2 hrs       Weekly  1 x N/O, 16 Amps  230VAC  UNO-QRS-230VAC
          - Battery backup.                    - 1 module width 17.5mm.
          - Australian daylight savings time.
          - 24 hour or 7 days program.
          - 16A/250V AC switching.








                                                Battery   Minimum                        Supply
                                                back-up  switching time  Function  Contacts  voltage  Part No.
                                                DIN Rail / Surface / Panel Mount
                     UNO-D-230VAC               no       15 min.     Daily  1 x C/O, 16 Amps  230V AC  ALPHA-D-230VAC
                                                100 hrs  2 hrs       Weekly  1 x C/O, 16 Amps  230V AC  ALPHA-QRS-230VAC












                     ALPHA-D-230VAC
                                                Battery   Minimum                        Supply
                                                back-up  switching time  Function  Contacts  voltage  Part No.
                                                Modular DIN Rail Mount
                                                no       15 min.     Daily  1 x C/O, 16 Amps  230V AC  SUPRA-D-230VAC








                     SUPRA-D-230VAC



                                                Battery   Minimum                        Supply
                                                back-up  switching time  Function  Contacts  voltage  Part No.
                                                DIN Rail / Surface / Panel Mount
                                                100 hrs  15 min.     Daily  1 x C/O, 16 Amps  230V AC  MINIT-QRD-230VAC





                    MINIT-QRD-230VAC






          Datasheets & Function Diagrams available at ipd.com.au

    406   V16-IC-T&EC-R04                               www.ipd.com.au                             Phone: 1300 556 601
   409   410   411   412   413   414   415   416   417   418   419