Page 429 - V16 Catalogue Final
P. 429

ABB PHASE MONITORING RELAYS - DIN MOUNTING







                                                                 Measuring                  Control
                                          Function               Range    Time Range  Contacts  supply voltage  Part No.
                                          Multifunctional Single/Three phase monitoring
                                          Monitor Phase loss & undervolatge 380..480VAC Start-up delay:  1 x N/O  380..480VAC  CM-PBE.N
                                          L1,L2,L3=380-440VAC    (L-L),   500ms             (L-L) L-N
                                          L-N=220-240VAC         220-240VAC Tripping delay:
                                                                 (L-N)    150ms
                                         - 1 module width 22.5mm.

                    CM-PBE.N







                                                                 Measuring                  Control
                                          Function               Range    Time Range  Contacts  supply voltage  Part No.
                                                                                                                  TIMERS &
                                          Multifunctional three phase monitoring                                 CONTROL RELAYS
                                          Monitor Phase loss & undervolatge 380..480VAC Start-up delay:  1 x N/O  380..480VAC  CM-PBE
                                          L1,L2,L3=380-440VAC    (L-L)    500ms             (L-L)
                                                                          Tripping delay:
                                                                          150ms
                                         - 1 module width 22.5mm.
                     CM-PBE









                                                                 Measuring                  Control
                                          Function               Range    Time Range  Contacts  supply voltage  Part No.
                                          Three phase monitoring
                                          Monitor Phase sequence  208-440VAC Start-up delay:  1 x  208-440VAC  CM-PFE
                                          L1,L2,L3=208-440VAC    (L-L)    500ms     CO(SPDT) (L-L)
                                                                          Tripping delay:
                                                                          500ms
                                         - 1 module width 22.5mm
                     CM-PFE







                                          Monitor Phase failure detection,   200-500VAC Start-up delay:  2 x  200-500VAC  CM-PFS.S
                                          monitor phase sequence  (L-L)   500ms     CO(SPDT) (L-L)
                                          L1, L2, L3=200-500VAC
                                         - 1 module width 22.5mm


                    CM-PFS.S











        Phone: 1300 556 601                            www.ipd.com.au                               V16-IC-T&EC-R04  421