HVI Conductor
2 Connection Elements for HVI long Conductor
Connection kit for HVI long Conductor Ø20 mm, installation inside the supporting tube 819 145 HVI LO ASS RIV 20
Connection elements for sealing the HVI long Conductor at both ends, for implementing the sealing end of the conductor in the supporting
tube (head piece) and connection element for connection to other parts of the external lightning protection system or earth-termination 819 145 pc(s) 75,19 € 4013364152533 01 07 01 01 377 g 1
system (incl. two heat-shrinkable sleeves).
These connection elements may be used with HVI long supporting tubes.
Part No. 819 145
Material StSt
Connection bolt Ø10 mm, L 50 mm
Diameter Ø connection element 23 mm
PU 1 pc(s)
Connection kit for HVI long Conductor Ø20, mm installation outside the supporting tube 819 146 HVI LO ASS RAV MM 20
Connection elements for sealing the HVI long Conductor at both ends, for implementing the sealing end of the conductor outside the suppor-
ting tube (head piece for connection plate) and connection element for connection to other parts of the external lightning protection system 819 146 pc(s) 80,86 € 4013364152540 01 07 01 01 389 g 1
or earth-termination system (incl. two heat-shrinkable sleeves and four cable ties).
These connection elements may only be used for HVI long supporting tubes in combination with the fixing kit (Part No. 819 294).
Part No. 819 146 HVI Conductor
Material StSt
Connection bolt Ø10 mm, L 50 mm
Diameter Ø connection element 23 mm
PU 1 pc(s)
Connection element (head piece) for HVI long Conductor Ø20, mm installation outside the supporting tube 819 197 AEA KO HVI 20 SW V2A
Connection element for sealing the HVI long Conductor, for implementing the sealing end of the conductor on the outside of the supporting
tube (head piece for connection plate). Incl. one heat-shrinkable sleeve and two cable ties. 819 197 pc(s) 44,50 € 4013364222236 01 07 01 01 195 g 1
Part No. 819 197
Material StSt
Connection M12 thread
Diameter Ø connection element 23 mm
PU 1 pc(s)
Connection element for HVI long Conductor Ø20 mm 819 199 AE BO10 HVI 20 SW V2A
Connection element for sealing the HVI long Conductor, for implementing the sealing end of the conductor for other parts of the external
lightning protection or earth-termination system. Incl. one heat-shrinkable sleeve and two cable ties. 819 199 pc(s) 35,64 € 4013364222274 01 07 01 01 198 g 1
Part No. 819 199
Material StSt
Connection bolt Ø10 mm, L 50 mm
Diameter Ø connection element 23 mm
PU 1 pc(s)
Connection kit for HVI long Conductor Ø23, mm installation inside the supporting tube 819 147 HVI LO ASS RIV 23
Connection elements for sealing the HVI long Conductor at both ends, for implementing the sealing end of the conductor inside the suppor-
ting tube (head piece) and connection element for connection to other parts of the external lightning protection or earth-termination system 819 147 pc(s) 76,22 € 4013364152557 01 07 01 01 394 g 1
(incl. four heat-shrinkable sleeves).
These connection elements may be used with HVI long supporting tubes.
Part No. 819 147
Material StSt
Connection bolt Ø10 mm, L 50 mm
Diameter Ø connection element 23 mm
PU 1 pc(s)
Connection kit for HVI long Conductor Ø23, mm installation outside the supporting tube 819 148 HVI LO ASS RAV 23
Connection elements for sealing the HVI long Conductor at both ends, for implementing the sealing end of the conductor outside the sup-
porting tube (head piece for connection plate) and connection element for connection to other parts of the external lightning protection or 819 148 pc(s) 81,89 € 4013364152564 01 07 01 01 419 g 1
earth-termination system (incl. four heat-shrinkable sleeves and four cable ties).
These connection elements may only be used with the fixing kit (Part No. 819 294) and with HVI supporting tubes.
Part No. 819 148
Material StSt
Connection bolt Ø10 mm, L 50 mm
Diameter Ø connection element 23 mm
PU 1 pc(s)