Page 190 - dehn-catalogue-lightning-protection_3
P. 190
HVI Conductor
Conductor holder for HVI Conductor
275 220 LH ZS 20 H19 IGM8 GR PA
275 225 LH ZS 23 H19 IGM8 GR PA
For wall mounting and for mounting in the sealing end range.
275 220 4013364103450 01 07 01 01 17 g 25
pc(s) 3,13 €
Part No. 275 220 275 225
275 225 4013364103467 01 07 01 01 17 g 25
pc(s) 3,13 €
Material of conductor holder PA PA
Conductor support Rd 20 mm 23 mm
Female thread M8 M8
Fixing hole 6.5 mm 6.5 mm
Screw r M6 x 16 mm r M6 x 16 mm
PU 25 pc(s) 25 pc(s)
Conductor holder for HVI Conductor
275 229 LH ZS 20 H10 B6.5X16 V2A
For wall mounting with two-screw clamp (not for use in the sealing end range).
275 229 4013364102040 01 07 01 01 59 g 50
pc(s) 5,90 €
Part No. 275 229
Material of conductor holder StSt
Conductor support Rd 20 mm
Fixing hole 6.5 x 16 mm
Screw dm M6 x 14 mm
HVI Conductor PU 50 pc(s)
Conductor holder for HVI Conductor
LH ZS 23 H10 B6.5X16 V2A
275 239
For wall mounting with two-screw clamp (not for use in the sealing end range).
275 239 4013364115811 01 07 01 01 73 g 1
pc(s) 5,96 €
Part No. 275 239
Material of conductor holder StSt
Conductor support Rd 23 mm
Fixing hole 6.5 x 16 mm
Screw d m M6 x 14 mm
Standard EN 62561-4
PU 1 pc(s)
Sign
480 598 HWS 300X200 AGBS HVI DE EN K
Front in German ACHTUNG! Getrennter Blitzschutz mit HVI Leitung
480 598 4013364105607 01 07 01 01 80 g 1
pc(s) 11,69 € Back in English ATTENTION! Separated Lightning Protection with HVI conductor system
Part No. 480 598
Material plastic
Dimensions (l x w x d) 300 x 210 x 1 mm
Fixing [4x] Ø6.5 mm
Hole distance 270 / 180 mm
PU 1 pc(s)
Sign
480 599 HWS 70X30 APA DE EN K
Front in German ACHTUNG! Potentialausgleich
480 599 4013364105614 01 07 01 01 9 g 1 Back in English ATTENTION! Equipotential Bonding
pc(s) 4,83 €
Hole distance suitable for two-screw clamp (Part No. 480 291).
Part No. 480 599
Material plastic
Dimensions (l x w x d) 70 x 30 x 1 mm
Fixing [2x] Ø6.5 mm
Hole distance 38 mm
PU 1 pc(s)
7 Conductor Holders for HVI Conductor in Ex Areas
The HVI Conductor is suitable for use in explosion hazardous areas of Ex zone 1 (gases, vapours, mists) as well as Ex zone 21 (dusts). The spe-
cial installation conditions safely prevent electric sparks to neighbouring metal parts when lightning current flows through the HVI Conductor.
The HVI Conductor has to be installed in explosion hazardous areas in accordance with the installation instructions.
HVI Ex W70 holder
275 440 LH ZS 20 EX W70 BP V2A
For fixing to metal structural parts (façades) in Ex zones 1 and 21.
275 440 4013364146914 01 07 01 01 152 g 10
pc(s) 27,09 €
Part No. 275 440
Material StSt
Conductor support Rd 20 mm
Distance from wall 70 mm
Fixing [4x] Ø5.1 / [2x] 7 x 10 mm
PU 10 pc(s)
186 Detailed product information can be found on our website Valid as of March 1, 2020