Page 192 - dehn-catalogue-lightning-protection_3
P. 192
HVI Conductor
8 Connecting Components 200 kA (10/350 μs)
For use in class of LPS I and II (LPL I, II).
Clamps are tested with a 200 kA (10/350 µs) lightning impulse current, based on EN 62561-1.
UNI disconnecting clamp for two round conductors
459 200 UTK 200 2X10 FL30 ZP V2A
Part No. 459 200
459 200
Material StSt
Clamping range Rd / Rd 10 / 10 mm
4013364155527 01 04 01 03 132 g 1 pc(s) 10,92
€
Clamping range Rd / Fl 10 / 30 mm
Lightning current carrying capability (10/350 µs) 200 kA
Standard based on EN 62561-1
PU 1 pc(s)
UNI disconnecting clamp for earth entry rods
459 219 UTK 200 8.10 16 ZP V2A
Part No. 459 219
459 219
Material StSt
4013364158221 01 04 01 03 126 g 1 pc(s) 12,36
€
Clamping range Rd / Rd
8-10 / 16 mm
HVI Conductor Lightning current carrying capability (10/350 µs) 200 kA
based on EN 62561-1
Standard
1 pc(s)
PU
Clamping piece
380 209 KS 200 B11.11 FL30X4 V2A
Part No. 380 209
380 209
Material StSt
Clamping range Fl 30 x 4 mm
4013364158269 01 04 01 02 102 g 1 pc(s) 17,51
€
Lightning current carrying capability (10/350 µs) 200 kA
Standard based on EN 62561-1
PU 1 pc(s)
KS connector
301 209 KSV 200 10 FER V2A
Part No. 301 209
301 209 4013364158252 01 04 01 02 59 g 1
pc(s) 14,83 €
Material StSt
Clamping range Rd 10 mm
Lightning current carrying capability (10/350 µs) 200 kA
Standard based on EN 62561-1
PU 1 pc(s)
MV clamp for round conductors
390 209
MVK 200 8.10
SKM10X30
V2A
Part No. 390 209
390 209
Material StSt
4013364158245 01 04 01 01 104 g 1 pc(s) 11,64
€
Clamping range Rd / Rd 8-10 mm
Lightning current carrying capability (10/350 µs) 200 kA
Standard based on EN 62561-1
PU 1 pc(s)
392 209
MVK 200 8.10 MV clamp for air-termination rods
16 SKM10X40
FSC V2A
Part No. 392 209
392 209 4013364158238 01 04 01 01 140 g 1
pc(s) 12,41 €
Material StSt
Clamping range Rd / Rd 8-10 / 16 mm
Lightning current carrying capability (10/350 µs) 200 kA
Standard based on EN 62561-1
PU 1 pc(s)
DECLARATION OF MANUFACTURER
Product: UNI Disconnecting Clamps 200 kA
Product designation: Part No. 459200
Part No. 459219
Type: UTK 200 2X10 FL30 ZP V2A
UTK 200 8.10 16 ZP V2A
Manufacturer: DEHN SE + Co KG
Hans-Dehn-Straße 1
92318 Neumarkt, Germany
Application:
The UNI disconnecting clamps are used as lightning current carrying capable connections
from air-termination tips or rods to conductors respectively from down conductors to the
earth entries, as per IEC 62305-3 (VDE 0185-305-3) and DIN EN 62561-1 (VDE 0185-561-1).
We herewith confirm that the UNI disconnecting clamps are suitable for use in Ex zone 2 (gas,
vapour, mist) and Ex zone 22 (dust).
The UNI disconnecting clamps have no potential source of ignition (component) of their own
and are thus not subject to the European directive ATEX 2014/34/EU.
Therefore, approval according to the European directive ATEX 2014/34/EU is legally
impossible and not required from an explosion protection point of view.
Neumarkt, September 24th, 2019
Dr.-Ing. Ralph Brocke
Director R&D
188 Detailed product information can be found on our website Valid as of March 1, 2020
Declaration of Manufacturer_UNI Disconnecting Clamp 2 4.09.2019 1 of 1