4. Carry out Earthing and Short-Circuiting – EaS Devices
Phase Screw Clamp ... with Safety Bow 784 038 PSK 10 32 SQL SB
Ideally suited for use in inclined positions.
784 038 4013364138452 05 00 04 08 1.01
kg 394,00 €
Type PSK 10 32 SQL SB PSK 10 32 SQL
Part No. 784 038 784 032
Clamping range Ø 10 ... 32 mm 10 ... 32 mm
Anti-rotation element PK2 PK2
For cable cross-section Cu 16 ... 95 mm 2 16 ... 95 mm 2 784 032 PSK 10 32 SQL
Max. short-circuit current Ik 0.5 s 18.7 kA 18.7 kA 784 032 4013364018679 05 00 04 08 969 g
356,00 €
Max. short-circuit current Ik 1 s 18.7 kA 18.7 kA
Rigid Ball Head Cap 772 314 772 324 KKH 20 SQL
KKH 25 SQL
Type KKH 20 SQL KKH 25 SQL
772 314 4013364080171 05 00 04 08 446 g
81,00 €
772 324 4013364080188 05 00 04 08 719 g
101,00 €
Part No. 772 314 772 324
For fixed ball point Ø 20 mm 25 mm
Anti-rotation element PK1 PK1
For cable cross-section Cu 16 ... 120 mm 2 16 ... 150 mm 2
Max. short-circuit current Ik 0.5 s 33.5 kA 42.0 kA
Max. short-circuit current Ik 1 s 23.7 kA 29.6 kA
Universal Clamp
773 236 UK 25 SQL
773 331 UK 30 SQL
Type UK 25 SQL UK 30 SQL
773 236 4013364114579 05 00 04 08 714 g
85,00 €
773 331 4013364069244 05 00 04 08 793 g
94,00 €
Part No. 773 236 773 331
For fixed ball point Ø 20 / 25 mm 25 / 30 mm
For T pins with a collar width of 15 mm 18 mm
Rd / Fl clamping range 20 mm 30 mm
Anti-rotation element PK1 PK1
For cable cross-section Cu 16 ... 120 mm 2 16 ... 120 mm 2
*)
*)
Max. short-circuit current Ik 0.5 s 33.5 kA 33.5 kA
Max. short-circuit current Ik 1 s 23.7 kA 23.7 kA
*) See table for “Clamping range and maximum cable cross-section of universal clamps used for“ *) Clamping range and maximum cable cross-section of
universal clamps used for:
Max. cable
Rd / Fl
Fixed ball point T Pin Clamping cross-section
Ø Collar width
The clamps must be designed for the same maximum short-circuit current as the earthing and range Cu
short-circuiting cables! 20 / 25 / 30 mm 15 / 18 mm 20 / 30 mm 16 mm 2
20 / 25 / 30 mm 15 / 18 mm 20 / 30 mm 25 mm 2
20 / 25 / 30 mm 15 / 18 mm 20 / 30 mm 35 mm 2
20 / 25 / 30 mm 15 / 18 mm 20 / 30 mm 50 mm 2
20 / 25 / 30 mm 15 / 18 mm 20 / 30 mm 70 mm 2
20 / 25 / 30 mm 15 / 18 mm — 95 mm 2
— / 25 / 30 mm — — 120 mm 2
— — — 150 mm 2
Accessories for Phase Connecting Elements for Overhead Lines
Two-pole phase connecting plate 728 312 PAP 2 M12 SSM B13
Allows to connect two phase screw clamps with PK1 anti-rotation element.
728 312 4013364128712 05 00 04 06 270 g
91,00 €
Type PAP 2 M12 SSM B13
Part No. 728 312
Anti-rotation cable lug PK1
Borehole Ø12.5 mm
Max. short-circuit current Ik 0.5 s 33.5 kA
Max. short-circuit current Ik 1 s 23.7 kA
4. EaS Devices
728 313 PAP 3 M12 SSM B13 RB
Three-pole phase connecting plate with round pin 728 313 4013364157132 05 00 04 06 612 g
219,00 €
Phase connecting plate for phase clamps.
Type PAP 3 M12 SSM B13 RB
Part No. 728 313
Anti-rotation cable lug PK1
Borehole Ø12.5 mm
Max. short-circuit current Ik 0.5 s 33.5 kA
Max. short-circuit current Ik 1 s 23.7 kA
Valid as of January 1, 2019 You will find detailed product information on our website 73
S e D 4. a E 4. s EaS Devices i v e c a S E 4 . D e s c e v i