Page 10 - dehn-protects-the-railway-infrastructure
P. 10

Source: PINTSCH BAMAG






            DEHN Test Centre                                                                                                          DEHN protects.
                                                                                                                                                          ®
                                                                                                                                      Experienced, reliable and globally active



            Our test centre with a floor space of 800 m  is equipped   Labour protection legislation requires periodic                DEHN has been at home in many areas of railway technol-  Many renowned companies in the railway infrastructure
                                              2
            with the latest devices and technologies to perform light-  inspections:                                                  ogy for decades now. We see it as our job to make systems   sector put their trust in sophisticated DEHN technology.
            ning current tests on products, installations and systems.   Electrical work equipment must be safe. This is the respon-  and applications continually safer and more efficient.
            Our lightning impulse current laboratory, which is part of   sibility of the employer. Defective work equipment endan-    This is why we maintain a close educational partnership   A selection of safety-conscious partners can be found
            our test centre, is able to generate lightning currents with   gers employees and, time and again, causes accidents. For   with the VDEI (Verband Deutscher Eisenbahn-Ingenieure   below:
                                                                                                                                      e. V. – Association of German Railway Engineers).
            a peak value up to 400 kA (10/350 µs) making it one of   this reason, the German labour protection law calls for
            the most powerful of its kind in the world. DAkkS* accred-  regular tests. “Periodic inspections” aim to ensure that
            itation confirms that the DEHN Test Centre has both the   voltage detectors and EaS devices are in impeccable
            technical prerequisites and the high level of competence to   condition.                                                  •  AREX Sp. z o.o.,                             •  Rail Power Systems GmbH,
            conduct those tests described in the scope of accredita-                                                                    Gdynia (Polen)                                   München
            tion. This is based on the relevant national and internation-  Have your equipment tested regularly at the DEHN
            al standards.                                    service centre:
                                                                                                                                      •  BBR Verkehrstechnik GmbH,                    •  Scheidt & Bachmann GmbH,
            The services of the DEHN test laboratory include:  •  We test your voltage detectors in our high-voltage                    Braunschweig                                     Mönchengladbach
                                                               test laboratories
            •  Test of surge protective devices and external lightning   •  Non-destructive testing of your EaS devices; if desired,
               protection components                           we come to you                                                         •  ESA Elektroschaltanlagen                     •  Siemens Mobility GmbH,
            •  High-voltage test with lightning impulses     •  Includes documentation of test via marking on the                       Grimma GmbH, Grimma                              Braunschweig
            •  Complete lightning current tests for low-voltage   device itself and in a separate test report
               distribution boards and signalling systems    •  A further advantage:                                                  •  Firmengruppe Max Bögl,
            •  Surge immunity test for telecommunications systems  •  We test models from all manufacturers!                            Neumarkt i. d. OPf.                           •  SPITZKE SE, Großbeeren

                                                             * German Accreditation Body
                                                                                                                                      •  PINTSCH ABEN B.V.,                           •  STRABAG Rail Fahrleitungen
                                                                                                                                        Maarssen (Niederlande)                           GmbH, Berlin


                                                                                                                                                                                      •  Verband Deutscher Eisenbahn-
                                                                                                                                      •  PINTSCH BAMAG Antriebs- und                     Ingenieure e. V. – VDEI,
                                                                                                                                        Verkehrstechnik GmbH, Dinslaken
                                                                                                                                                                                         Frankfurt am Main









    18                                                                                                                                                                                                                                    19
   5   6   7   8   9   10