Page 6 - dehn-protects-the-railway-infrastructure
P. 6

Protection of level crossing safety systems                                                                               Selection guide: Protection of level crossing safety systems





            Level crossings are now, more than ever, neuralgic points   With its wide product portfolio for lightning and surge        Application                                     Type                                  Part No.
            whose protection requires maximum reliability. Level cross-  protection, DEHN has the optimum prerequisites for creat-
            ings systems ensure that intersections where a railway line   ing bespoke solutions for level crossings. To ensure that    Protection of the power supply 400/230 V, 50 + 16,7 Hz
            crosses a road or path at the same level are safe. Modern   these systems also function reliably during thunderstorms                    Three-phase type 1+2+3            DEHNventil ®      DV M TT 255 FM      951 315
            level crossing systems can either be integrated in an inter-  DEHN, in cooperation with manufacturers of level crossing                  Single-phase type 1+2+3                             DV M TT 2P 255 FM   951 115
            locking or function autonomously. Nowadays, they are   safety systems and the DB Netz AG, has developed a spe-
            equipped with fully electronic high-performance control   cial protection concept which offers you the following
            technology and are, therefore, particularly vulnerable to   benefits:                                                                    Three-phase type 2                DEHNguard ®       DG M TT 275 FM      952 315
            disturbances such as direct lightning or surges. As level   •  Approved by the Federal Railway Authority                                 Single-phase type 2                                 DG M TT 2P 275 FM   952 115
            crossings cover a wide area, the peripheral elements are    (Eisenbahn-Bundesamt)
            often a considerable distance away from the switching   •  Laboratory-tested protection solutions                          Protection of the DC voltage level supplied via charging rectifiers
            house. Field impulses triggered by lightning strikes can                                                                                                                             ®
            generate induction voltage in conductor loops and switch-  •  Personal protection due to maximum safety                                  24 V DC / 18 V DC                 BLITZDUCTOR  XT   BXT ML4 BD 24       920 344
                                                                                                                                                     36 V DC
                                                                                                                                                                                                         BXT ML4 BE 36
                                                                                                                                                                                                                             920 336
            ing circuits which far exceeds the insulation strength of the   •  Maximum system availability                                           60 V DC                                             BXT ML4 BD 60       920 346
            electronic/electric devices in use.              •  Remote signalling of arresters to be replaced                                        Base part for BLITZDUCTOR ®  XT                     BXT BAS             920 300
                                                             •  Device and component protection
                                                                                                                                       Protection of status monitoring
                                                             •  Space-saving protection elements                                                     Condition monitoring of up to 10 BXTs  DEHNrecord   DRC MCM XT          910 695



                                                                                                                                       Permanent interference voltage – link
                                                                                                                                                     MOV arrester, UC 275 V AC         DEHNguard ®       DG S 275 FM         952 090
                                                                                                                                                     GDT arrester, UC 255 V AC         DEHNgap           DGP C S FM          952 035


                                                                                                                                       Earthing
                                                                                                                                                     Components for earthing level crossing   Earth rod StSt V4A  TE 20 1500 AZ V4A  620 902
                                                                                                                                                     safety systems                    Voltage-limiting device  SDS 1        923 110
                                                                                                                                                                                       Mast adapter      MA SDS M12          723 199








    10                                                                                                                                                                                                                                    11
   1   2   3   4   5   6   7   8   9   10