Page 12 - ferraz-usa-solar-brochure-short
P. 12

DfC series



                  Dead-front fuse Covers





                  Mersen DFC dead-front fuse covers snap onto individual fuses installed in
                  fuse blocks, covering exposed live clips and terminals, reducing accidental
                  contact by personnel. They are sized to fit Mersen HP6J Class J and
                  HP10M or HP6M midget PV fuses for increased safety and (optional)
                  open-fuse indication. All DFC dead-front fuse covers are reusable when a
                  fuse is replaced – simply detach from the open fuse and re-attach to the
                  new replacement fuse. On indicator models, an orange indicator light will
                  illuminate to indicate an open fuse. DFC fuse cover ends can be easily cut to
                  accommodate existing wiring, safety switches or special installations. A blank
                  label is provided with each DFC to write in circuit or fuse information.

                  Catalog numbers & Dimensions

                       Catalog Numbers        Fuses Accomodated       Dimensions (inches)
                   Non-indicating  indicating  Amps  Volts  Class    A     B     C
                   DFC-3     DFC-3I     65-100     600       J      7.57  1.30   2.20
                   DFC-7     DFC-7I      0-30      600      Midget  3.71  0.69   1.37      ratings:
                   DFC-12    DFC-12I    110-200    600       J      6.63  3.03   2.86      Non-Indicating
                  WARNING: To avoid electrical shock, TURN POWER OFF before installing, removing or servicing.  Volts   : 0 to 600VAC / DC
                  For a complete list of DFC covers please visit our website at us-ferrazshawmut.mersen.com.  Amps   : Fits fuses rated 0 to
                                                                                                     200A
                                                                                           Indicating
                                                                                           Volts   : 90 to 600VAC
                                                                                                   : 115 to 600VDC
                                                                                           Amps    : Fits fuses rated 0 to
                                                                                                     200A



                                                                                           approvals:
                                                                                           •   UL Listed (except midget size)
                                                                                               guide JDVS, File E90426
                                                                                           •   UL Recognized Component
                                                                                               (midget) guide JDVS2, File
                                                                                               E90426
                  fuses and fuse blocks for use with DfC                                   •   CSA Certified class 6228, File
                                                                                               70159
                      Fuse    Fuse Block   DFC
                   HP6J (65-100)  610xxHPJ  -3,-3I
                   HP6J (110-200)  620xxHPJ  -12,-12I
                   HP6M (1-30)  303xx   -7,-7I
                   HP10M (1-30)  303xx  -7,-7I
                  Note: DFC Covers fit single pole blocks and each pole of multi-pole blocks. Consult factory for data
                  sheets of DFC trim instructions for safety switches.