Page 8 - ferraz-usa-solar-brochure-short
P. 8
a150X 1000VDC
amp-trap form 101 fuses
®
protection for re-combiner applications
A150X Amp-Trap Form 101 fuses are rated up to 1000A, 1000VDC. They are suitable
for PV array overcurrent protection for re-combiner (sub-combiner, array combiner,
master combiner) applications.
Catalog numbers (amps)
A150X10-4 A150X45-4 A150X110-4 A150X400-4
A150X15-4 A150X50-4 A150X125-4 A150X450-4
A150X20-4 A150X60-4 A150X150-4 A150X500-4
A150X25-4 A150X70-4 A150X175-4 A150X600-4
A150X30-4 A150X80-4 A150X200-4 A150X800-4
A150X35-4 A150X90-4 A150X250-4 A150X1000-4
A150X40-4 A150X100-4 A150X300-4
Dimensions
Mounting Dimensions - Inches (mm)
Outline Reference Fig.
Type A B C D E F G H J
7.15 1.21 5.62 6.46 6.34 0.31 1.00 0.18 -
A150X10 to 60 4 1
(182) (31) (143) (164) (161) (8) (25) (3) -
7.87 1.50 5.62 6.93 6.31 0.40 1.00 .025 -
A150X70 to 100 4 1
(200) (38) (143) (176) (160) (10) (25) (6) -
7.87 2.00 5.62 6.93 6.31 0.40 1.50 0.25 -
A150X125 to 300 4 1
(200) (51) (143) (176) (160) (10) (38) (6) -
9.75 2.50 6.62 8.31 8.06 0.56 2.00 0.25 -
A150X400 to 600 4 1
(248) (64) (168) (211) (205) (14) (51) (6) -
9.87 3.50 6.12 8.03 7.71 0.56 2.75 0.37 1.37
A150X800 to 1000 4 2
(251) (89) (155) (204) (196) (14) (70) (9) (35)
Figure 1 Figure 2
ratings: approvals:
Volts : 1000VDC • Mersen self-certified
Amps : 10A to 1000A
I.R. : 100kA I.R. DC
Mersen • Solar Power Product Solutions 9