How to ORDER:





       The E630 system has been designed to be supplied in component blocks or Modules to build up a
       switchboard rated from 160A to 630A.


       The more common modules are available with some preassembly.
       Or components may be used for custom designs.



       Selection Steps:


       1. Incoming / CT /Metering and Outgoing Enclosure sizes


       2. Plinth sizes to suit

       3. Top Gland plates, Side Blank plates and Internal Glands/Blank plate


       4. Breakers, Chassis & Equipment


                    T
                             S

            6      Metering

                             S
                             S

            6       S CT

                             S              T-1      T-2

                             S                    G   C   S
                                                      a
                                                      b
                                           S CT
                   Incomer          6                 l                  T-1      T-2   T-2       T-1
            8      250A                               i
                                                      n
                                                  B   g   S                    B    G    G
                                                                                               Outgoing - 1
                             S               B                  6      Metering         A U   2 x FE Chassis
                                                                                        X
              Plinth                8            Outgoing
                    6                   Incomer   2 x FE                       B    G    G
                                         250A     Direct
                                                                               G    G    G
                                             B                                          C
                                                                                   C    a      Outgoing - 2
                                     Plinth                     6                  a    b     MCB 24P + AUX
                                                                        T CT       b    l
                                               8                                   l    i
                                                                                   i    n
                                                                               G   n G  g  G
                                                                                   g
                                                                               B              G
                                                                       Incomer          Outgoing   Outgoing
                                                                        630A
                                                                               B              G
                                                                   Plinth
                                                                         6         2       4          4





                                 IPD GROUP LIMITED   Phone: 1300 556 601   www.ipdgroup.com.au
   2   3   4   5   6   7   8