Air Circuit Breakers (ACB)



        AUTOMATIC AIR CIRCUIT BREAKERS


         Technical Data

         Common data
         Rated service voltage Ue      [V]  690
         Rated insulation voltage Ui   [V]  1000
         Rated impulse withstand voltage Uimp  [kV]  12
         Frequency                     [Hz]  50 - 60
         Number of poles                    3-4
         Version                            Fixed - Withdrawable
         Suitable for isolation according to  IEC 60947-2
         SACE Emax 3                                             E1.3   E2.3           E4.3           E6.3
         Performance levels                                      N      N       H      N              H
         Rated uninterrupted current Iu            [A]           250    800     800    3200           4000
         @ 40°C
                                                   [A]           630    1000    1000   4000           5000
                                                   [A]           800    1250    1250                  6300
                                                   [A]           1000   1600    1600
                                                   [A]           1250   2000    2000
                                                   [A]           1600   2500    2500
         Neutral pole current-carrying capacity for 4-pole CBs  [%Iu]  100  100  100   100     100    50-100
         Rated ultimate short-circuit  400-415 V   [kA]          66     66      100    66      100    100
         breaking capacity Icu
                                440 V              [kA]          66     66      100    66      100    100
                                500-525 V          [kA]          50     66      85     66      85     100
                                690 V              [kA]          50     66      85     66      85     100
         Rated service short-circuit breaking capacity Ics  [%Icu]  100 (1)  100  100  100     100    100
         Rated short-time withstand  (1s)          [kA]          50     66      85     66      85     100
         current Icw            (3s)               [kA]          30     50      66     50      75 (2)  100
         Rated short-circuit making  400-415 V     [kA]          145    145     220    145     220    220
         capacity (peak value) Icm
                                440 V              [kA]          145    145     220    145     220    220
                                500-525 V          [kA]          105    145     187    145     187    220
                                690 V              [kA]          105    145     187    145     187    220
         Utilization category (according to IEC 60947-2)         B      B       B      B       B      B
         Breaking (2)           Breaking time for I<Icw  [ms]    40     40      40     40      40     40
                                Breaking time for I>Icw  [ms]    25     25      25     25      25     25

         1) Ics : 50kA for 400V…440V voltage; 2) Total clearing time is the sum of breaking time and trip time

         Dimensions and weight
         Dimensions             H - Fixed/Withdrawable  [mm]                           371/425        371/425
                                D - Fixed/Withdrawable  [mm]                           277/390        277/390
                                W - Fixed 3p/4p    [mm]                                384/510        762/888/1014
                                W - Withdrawable 3p/4p  [mm]                           425/551        803/929/1069
         Weights (CB with trip unit/  Fixed 3p/4p  kg                                  58/73          112/127/143
         current sensors/standard   Withdrawable 3p/4p                                 114/140        211/237/237
         accessories)
                                including fixed part
         SACE Emax 3                                             E1.3   E2.3           E4.3           E6.3
         Mechanical life with regular              [Iu]          1600   1600    2500   < 2500  3200   4000
         maintenance prescribed by the
         manufacturer                              [No. cycles x 1000]  20  25  20     20      20     12
                                Frequency          [Oper./Hour]  60     60      60     60      60     60
         Electrical life with regular   440 V      [No. cycles x 1000]  8  12   8      10      7      4
         maintenance prescribed by the   690 V     [No. cycles x 1000]  6,5  10  7     10      7      4
         manufacturer
                                Frequency          [Oper./Hour]  30     30      30     20      20     10