Page 547 - IPD Product Catalog V17
P. 547
Sensors
PRESSURE SENSORS - DMP 331P
Ordering Code DMP 331P
DMP 331P - - - - - - - - -
Pressure Gauge 5 0 0
Absolute 5 0 1
Input [bar]
0.10 (1) 1 0 0 0
0.16 (1) 1 6 0 0
0.25 (1) 2 5 0 0
0.40 4 0 0 0
0.60 6 0 0 0
1.0 1 0 0 1
1.6 1 6 0 1
2.5 2 5 0 1
4.0 4 0 0 1
6.0 6 0 0 1
10 1 0 0 2
16 1 6 0 2
25 2 5 0 2
40 4 0 0 2
-1 - 0 X 1 0 2
Customer 9 9 9 9
Output
4 - 20mA / 2-wire 1
0 - 20mA / 3-wire 2
0 - 10V / 3-wire 3
Intrinsic Safety 4 - 20mA / 2-wire E
SIL2 4 - 20mA / 2-wire 1S
SIL2 with Intrinsic Safety 4 - 20mA / 2-wire ES
Customer 9
Accuracy
Standard for P N ≥ 0.4bar: 0.35% FSO 3
Standard for P N < 0.4bar: 0.50% FSO 5
Option for P N ≥ 0.4bar: 0.25% FSO 2
Customer 9 4
Electrical Connection
Male and female plug ISO 4400 1 0 0
Male plug Binder Series 723 (5-pin) 2 0 0
Cable outlet with PVC cable (IP67) (2) T A 0
Cable outlet, cable with ventilation tube (IP68) (3) T R 0
Male plug M12 x 1 (4-pin) / metal M 1 0
Compact field housing Stainless Steel 1.4301 (304) (4) 8 5 0
Customer 9 9 9
Mechanical Connection
G1/2” with flush welded diaphragm (DIN 3852) (5) Z 0 0
G3/4” with flush welded diaphragm (DIN 3852) Z 3 0
G1” with flush welded diaphragm (DIN 3852) Z 3 1
G1” DIN 3852 with rad. o-ring and flush diaphragm (6) Z 5 7
G1/2” DIN 3852 with rad. o-ring and flush diaphragm Z 6 1
G 1” cone K 3 1
Clamp DN 25 / 1” (DIN 32676) / 3A C 6 1
Clamp DN 32 / 1 1 / 2” (DIN 32676) / 3A C 6 2
Clamp DN 50 / 2” (DIN 32676) / 3A C 6 3
Clamp 3 / 4” (DIN 32676) / 3A C 6 9
Dairy pipe DN 25 (DIN 11851) (4) M 7 3
Dairy pipe DN 50 (DIN 11851) (4) M 7 5
Dairy pipe DN 40 (DIN 11851) (4) M 7 6
Varivent® DN 40/50 / 3A P 4 1
Customer 9 9 9
Diaphragm
Stainless Steel 1.4435 (316L) 1
Tantalum T
Hastelloy® C-276 (2.4819) H
Customer 9
Seals
For clamp, dairy pipe, Varivent®: Without 0
For inch thread - standard: FKM 1
For inch thread - option: FFKM 7
Customer 9
Filling Fluids
Silicone oil 1
Food compatible oil (FDA) / 3A 2
Customer 9
Special Version
Standard 0 0 0
With cooling element up to 300°C / 3A 2 0 0
Customer 9 9 9
(1) Absolute pressure possible from 0.4bar
(2) Standard: 2m PVC cable without ventilation tube (permissible temperature: -5°C to 70°C), others available on request.
(3) Code TR0 = PVC cable, cable with ventilation tube available in different types and lengths.
(4) For compact field housing electrical connection with dairy pipe mechanical connection option, the cup nut has to be mounted at the production stage of the pressure transmitter. The cup nut has
to be ordered separately.
(5) Possible only for P N ≥ 1bar
(6) Possible only for P N ≤ 2bar
Varivent® is a brand name of GEA Tuchenhagen GmbH, Hastelloy® is a brand name of Haynes International Inc.
1300 556 601 | ipd.com.au | V17-R05 547