Page 552 - IPD Product Catalog V17
P. 552
Sensors
LEVEL SENSORS - LMP 307
Ordering code LMP 307
LMP 307 - - - - - - - - -
Pressure
In bar 4 5 0
In mH O 4 5 1
2
Input [mH O] [bar]
2
1.0 0.10 1 0 0 0
1.6 0.16 1 6 0 0
2.5 0.25 2 5 0 0
4.0 0.40 4 0 0 0
6.0 0.60 6 0 0 0
10 1.0 1 0 0 1
16 1.6 1 6 0 1
25 2.5 2 5 0 1
40 4.0 4 0 0 1
60 6.0 6 0 0 1
100 10 1 0 0 2
160 16 1 6 0 2
250 25 2 5 0 2
Customer 9 9 9 9
Housing
Stainless Steel 1.4404 (316L) 1
Customer 9
Diaphragm
Stainless Steel 1.4435 (316L) 1
Customer 9
Output
4 - 20mA / 2-wire 1
0 - 20mA / 3-wire 2
0 - 10V / 3-wire 3
Intrinsic Safety 4 - 20mA / 2-wire E
SIL2 4 - 20mA / 2-wire 1S
SIL2 with Intrinsic Safety 4 - 20mA / 2-wire ES
Customer 9
Seal
FKM 1
EPDM 3
DVGW/KTW: EPDM (1) 3T
Petrol version: Without (welded version) (2) (4) 21
Customer 9
Accuracy
Standard for P ≥ 0.4bar 0.35% FSO 3
N
Standard for P < 0.4bar 0.5% FSO 5
N
Option 1 for P ≥ 0.4bar 0.25% FSO 2
N
Option 2 0.1% FSO 1
Customer (2) 9
Electrical Connection / Cable Length
PVC Cable (Grey, Ø 7.4mm) (3)
3m 1 0 0 3
5m 1 0 0 5
10m 1 0 1 0
15m 1 0 1 5
Special length in m 1 9 9 9
PUR Cable (Black, Ø 7.4mm) (3)
3m 2 0 0 3
5m 2 0 0 5
10m 2 0 1 0
15m 2 0 1 5
Special length in m 2 9 9 9
FEP Cable (Black, Ø 7.4mm) (3)
5m 3 0 0 5
10m 3 0 1 0
Special length in m 3 9 9 9
TPE-U Cable (Blue, Ø 7.4mm) (3)
Special length in m 4 9 9 9
DVGW/KTW: (1)
Special length in m F 9 9 9
Special version
Standard 0 0 0
Prepared for mounting with Stainless Steel 5 0 3
Customer 9 9 9
(1) Drinking water certification only possible with EPDM seal (code 3T) in combination with TPE-U cable (code F);
not possible with IS version (explosion protection)
(2 Not in combination with SIL
(3) Shielded cable with integrated ventilation tube for atmospheric pressure reference.
(4) Petrol version only in combination with FEP cable
552 1300 556 601 | ipd.com.au | V17-R05