Page 742 - Product Catalog V17 - Flip Book PDF
P. 742
Safety Automation & Control
SAFETY CONTROLLERS
PACSYSTEMS™ SAFETY CONTROLLER
Emerson’s standalone PACSystems Safety controller and Versamax SafetyNet IO system provides a high-performance IO System built on SIL2 safety
certifications. A crucial component of a cost-effective general safety solution, catering to a variety of markets, including Infrastructure, Emergency Shutdown
Systems (ESD), Fire & Gas, and Burner Management Systems (BMS). Our stand alone SIL2 Safety Controller is not just a component; it’s a cornerstone in the
foundation of your safety strategy. Trust in our proven technology to deliver performance, reliability, and ease of integration to your projects.
• For simplex and redundant operation, at incremental frame rates as fast as 3ms in any configuration.
• Built on a scalable, synchronised, hot-standby redundancy control platform, to ensure uninterrupted control of your applications and processes
with total transparency with switchover time as fast as 300 msec
• Supports Black Channel over EGD and OPC-UA Non-Transparent Server Redundancy, and Modbus TCP/IP.
• Managed and configured in PAC Machine Edition 10.7 and above with safety templates built for SIL2 systems, with support for up to 2000 Distributed
I/O points and advanced floating point (real) data functions.
RX3i Primary CPU RX3i Secondary CPU
Emerson Managed
Ethernet Switch
VersaMax Safety NIUs
Field Terminal Assembly
Features: PACSystem SIL2 Safety PLC Compatibility Selection Conformal coated Part Number
- Support PAC Machine Edition 10.7 RX3i Standalone Din Rail Controller IC695CPS400
- Secure Boot and Trusted Platform IC695CPS400CA
Module (TPM) RX3i Standalone Din Rail Controller Yes
- Multi-interface RJ45 Ethernet ports RX3i Controller Energy Pack 1 unit per Controller IC695ACC403SN
- Supports up to 2000 I/O points RX3i Controller Energy Pack 1 unit per Controller Yes IC695ACC403SNCA
- -40°C to 70°C (PLC Operating)
- Supply Voltage 18-24VDC at 20W PACSystem SIL2 Compatibility No. Conformal
- Safety Agency Approvals IEC 61508 Remote IO Selection No. Inputs Outputs coated Part Number
SIL2, NFPA 72/85/86/87, EN 54-2 with UL IO Rack Chasis
HazLoc C1D2 and CE Carrier Box Style 1 unit per IO Module IC200CHS022SN
IO Rack Chasis
Carrier Box Style 1 unit per IO Module Yes IC200CHS022SNCA
Power Supply 1 unit per IO System IC200PWR002SN
Power Supply 1 unit per IO System Yes IC200PWR002SNCA
Network Module 1 unit per IO System IC200SBI001
Network Module 1 unit per IO System Yes IC200SBI001CA
32 Points
Digital Input Module 1 unit per Chasis IC200MDL650SN
(4 Groups of 8)
32 Points
Digital Input Module 1 unit per Chasis Yes IC200MDL650SNCA
(4 Groups of 8)
Digital Output IC200MDL750SN
Module 1 unit per Chasis 32 Points
Digital Output
Module 1 unit per Chasis 32 Points Yes IC200MDL750SNCA
Analogue Input 1 unit per Chasis 15 Points IC200ALG264SN
Module (15BIT)
Analogue Input 1 unit per Chasis 15 Points Yes IC200ALG264SNCA
Module (15BIT)
742 1300 556 601 | ipd.com.au | V17-R12