PV Solutions



        SECONDARY GRID PROTECTION - ASSEMBLED SYSTEMS




         Standard requirements
         When making an application to connect solar photovoltaic systems (if your system
         is above 30kW three phases or 10kW single phase), the Distribution Network Service
         Provider (DNSP) will insist on secondary protection to be provided. This will be in addition
         to the in-built protection offered by AS 4777 compliant inverters. They will insist that the
         protection relay shall be certified. IPD offers you a complete range of Anti-islanding
         Relays and Fully assembled Grid protection systems. Our complete product range
         complies with the latest AS/NZS 4777 standards.

         In addition to the requirements of AS 4777 switchboards need to be tested to and
         compliant with the requirements of AS 61439 for current ratings above 125A. IPD’s
         Evolution boards have been tested to cover design verifications.



         Type: Secondary Protection + AC Control
         Fully assembled systems including protection relay, MCCB and AC contactor control.
         The ABB CM-UFD.M33 has been approved by local Australian Utility sector to provide
         secondary grid protection meeting the requirements of AS 4777.



         Type: Secondary Protection + AC Control + AC Combiner

         Fully assembled systems including MCCB, AC contactor control and AC combiner
         section. Three versions available ABB CM-UFD.M33 protection relay, ComAp MainsPro
         relay, both system voltage based for full export. Also included is an InteliProPV relay
         system for export limitation.




                                             PROTECTION CUBICLES WITH CM-UFD.M33
        Features:                             Rating          Rated Current    Dimensions (mm)
           - Compliant to AS 61439 switchboard Standard   (kVA)  AC21 (A)      W x H x D          Part No.
          along with AS 4777
           - AC Surge protection              Without AC Combiner
           - One hour battery back-up         69              100              600 x 600 x 200    PVAGPS4P69
           - Full size gland plate top and bottom in    110   160              600 x 600 x 200    PVAGPS4P110
          IP65 enclosure                      173             250              600 x 800 x 300    PVAGPS4P173
           - Mild-steel powder coated enclosure  277          400              600 x 1200 x 300   PVAGPS4P277
           - Optional Stainless steel outdoor version   436   630              600 x 1200 x 300   PVAGPS4P436
          available (make to order)
           - Add-on AC combiners with and without    With AC Combiner
          busbar system                       69              100              600 x 600 x 200    PVAGPS4P69AC18 (1)
                                              110             160              600 x 600 x 200    PVAGPS4P110AC18 (1)
                                              173             250              600 x 800 x 300    PVAGPS4P173AC18 (1)
                                             -  For systems greater than 173kVA ask your local IPD representative for a custom quote
                                              (1)  Including AC combiner section for up to 6 x 63A MCB’s