Page 832 - ABB_Motor _Protection_and_Control_catalogue_20221216
P. 832

10/6             ABB  MOTOR PROTECTION AND CONTROL

          —
          DRAF09 … DRAF16 enclosed direct-on-line starters





                                       L1 L2 L3  N
          Control supply wiring versions     V
                                          U
                  L1 L2 L3  N
                                       1  3  5       A1
                                      L1 L2 L3
                        V
                                                        U c =    U s
                    L1 U L2 L3  N  DRAF..S          DRAF..N            DRAF..P
                                 DRAF..U             A2
                          V       U U c c
                  1  3  5       I Separate supply   Phase-to-neutral   Phase-to-phase
                                 A1
                 L1 L2 L3 U           DRAF
                                    U c =    U s
                    1  3  5   O  A2  A1              A1                 A1
                   L1 L2 L3    R
           I  U U c c                U c =    U s       U c  = V           U c =    U
                 DRAF                 T1 T2 T3 6
                                       2
                                        4
                                  A2                 A2                 A2
               U U c c
          O  I     DRAF          A1
           R
                                    U c  = V
                  2  4  6
           O     T1 T2 T3        A2  A1
            R
                                     U c  = V
                    2  4  6
                   T1 T2 T3
                                  A2
          Wiring diagram
          Power circuit                                                              AC local control
                                                                                      DRAF..P                         +
                                                                                      DRAF..N  KM1: 5/L3
                                                                                      DRAF..S  Us
                                                                                      DRAF..U        A                  A
                                                                                                 RESET               RESET
                                                                                                     M      95           M      95
                                                                                                            96  FR1             96  FR1
                                                                                                   STOP               STOP
                                                                                                        -7                  -3
                                                                                                            13                  13
   10
                                                                                                      I      KM1          I     KM1
                                                                                                        -8  14              -4  14
                                                                                                            A1                 A1+
                                                                                      DRAF..U            KM1                KM1
         3-phase motor                      Phase-to-phase        Phase-to-neutral    DRAF..S  Us           A2                 A2-
                                            Single phase motor    Single phase motor
                                                                                      DRAF..N  N
                                                                                      DRAF..P  KM1: 3/L2              -


                                        131.5  5.18"
                                        126.5  4.98"
                                     60 2.36"
                   107 4.22"         8 .32"             2 x Ø 5.5 .22"         IEC starter types - ISO M20
                                                        M5
                                                                               Cable inlet      Cable outlet
                                                                               Enclosure top    Enclosure bottom
                                                                               2 x ø 20 mm      2 x ø 20 mm
                                                                               2 x ø 0.79"      2 x ø 0.79"


                             230 9.06"                  218 8.58"              UL starter types - NPT
                                                                               Cable inlet
                                                                                                Cable outlet
                                                                               Enclosure top    Enclosure bottom
         Ø 22.3 .88"
                                                                               1 x 3/4"         1 x 3/4"
                                                                               1 x 1/2"         1 x 1/2"



          DRAF09, DRAF12, DRAF16
          Main dimensions mm, inches
   827   828   829   830   831   832   833   834   835   836   837