Page 828 - ABB_Motor _Protection_and_Control_catalogue_20221216
P. 828

10/2             ABB  MOTOR PROTECTION AND CONTROL

          —
          DRAS09 … DRAS16 enclosed direct-on-line starters

          4 to 7.5 kW, protected by thermal overload relays
          AC or DC operated


                                    Enclosed direct-on-line (DOL) starters are used for controlling 3-phase asynchronous motors up
                                    to 690 V AC.
                                    Each starter is delivered assembled and wired. It contains:
                                    •  IP65 compact plastic enclosure with double insulation, equipped with:
                                        - 1 green flush "I" ON button and 1 red protruding "O" OFF/RESET button
                                        - 2 quarter-turn, quick fastening screws and a base with 6 cable inlets and outlets via knockouts.
                                    •  1 AS or ASL 3-pole contactor with holding contact
                                    •  1 PE and 1 neutral terminal.
                                    3 versions of control supply wiring are available: phase-to-phase, separate supply or phase-to-
                                 1SBC133003V0014  T16 thermal overload relay has to be ordered separately and choses according to motor's nominal
                                    neutral.
                                    current (see table below).
                                    DRAS, DRASL enclosed DOL starters
         DRAS
         + T16 to be ordered separately  IEC - AC-3       Rated control circuit   Control supply   Type   Order code  Weight
                                    Rated operational     voltage      wiring
                                                          Uc                                              Pkg
                                    power           max.   Other control                                  (1 pce)
                                    220 V  400 V  500 V  current  voltages see AS
                                    230 V           θ ≤ 40 °C  voltage code table
                                    240 V           Ue=400 V
                                    kW    kW   kW   A     V 50/60 Hz  V DC                                kg
                                    AC operated with AS 3-pole contactors
                                    2.2   4    4    9     24      -    Separate supply  DRAS09-20S  1SBK104235R2000  0.650
                                                          220     -    Phase-to-neutral  DRAS09-25N  1SBK104135R2500   0.650
                                                          230     -    Phase-to-neutral  DRAS09-26N  1SBK104135R2600  0.650
                                    3     5.5  5.5  12    24      -    Separate supply  DRAS12-20S  1SBK114235R2000  0.650
                                                          220     -    Phase-to-neutral  DRAS12-25N  1SBK114135R2500  0.650
                                                          230     -    Phase-to-neutral  DRAS12-26N  1SBK114135R2600  0.650
                                    4     7.5  7.5  15.5  24      -    Separate supply  DRAS16-20S  1SBK124235R2000  0.650
                                                          220     -    Phase-to-phase  DRAS16-25N  1SBK124135R2500  0.650
                                                          230     -    Phase-to-neutral  DRAS16-26N  1SBK124135R2600  0.650
                                    DC operated with ASL 3-pole contactors
                                    2.2   4    4    9     -       24   Separate supply  DRASL09-81S  1SBK104335R8100  0.700
                                    3     5.5  5.5  12    -       24   Separate supply  DRASL12-81S  1SBK114335R8100  0.700
                                    4     7.5  7.5  15.5  -       24   Separate supply  DRASL16-81S  1SBK124335R8100  0.700
   10
                                    T16 thermal overload relays to be ordered separately
                                    Setting range   Short-circuit      Trip class  Type     Order code    Weight
                                                    protective device                                     (1 pce)
                                    A                                                                     kg
                                    0.10…0.13       0.5 A, Fuse type T  10        T16-0.13  1SAZ711201R1005  0.100
                                    0.13…0.17       1.0 A, Fuse type T            T16-0.17  1SAZ711201R1008  0.100
                                    0.17…0.23
                                                                                            1SAZ711201R1009
                                                                                                          0.100
                                                                                  T16-0.23
                 2CDC231009V0013    0.23…0.31       2.0 A, Fuse type gG           T16-0.31  1SAZ711201R1013  0.100
                                    0.31…0.41
                                                                                  T16-0.41
                                                                                                          0.100
                                                                                            1SAZ711201R1014
                                                                                                          0.100
                                    0.41…0.55
                                                                                            1SAZ711201R1017
                                                                                  T16-0.55
                                    0.55…0.74
                                                                                                          0.100
                                                                                            1SAZ711201R1023
                                                                                  T16-1.0
                                    0.74…1.00       4.0 A, Fuse type gG           T16-0.74  1SAZ711201R1021  0.100
                                                    6.0 A, Fuse type gG
         T16
                                    1.00…1.30                                     T16-1.3   1SAZ711201R1025  0.100
                                    1.30…1.70       10.0 A, Fuse type gG          T16-1.7   1SAZ711201R1028  0.100
                                    1.70…2.30                                     T16-2.3   1SAZ711201R1031  0.100
                                    2.30…3.10                                     T16-3.1   1SAZ711201R1033  0.100
                                    3.10…4.20       20.0 A, Fuse type gG          T16-4.2   1SAZ711201R1035  0.100
                                    4.20…5.70                                     T16-5.7   1SAZ711201R1038  0.100
                                    5.70…7.60       35.0 A, Fuse type gG          T16-7.6   1SAZ711201R1040  0.100
                                    7.60…10.0                                     T16-10    1SAZ711201R1043  0.104
                                    10.0…13.0       40.0 A, Fuse type gG          T16-13    1SAZ711201R1045  0.104
                                    13.0…16.0                                     T16-16    1SAZ711201R1047  0.104
                                    Empty enclosure with push-button
                                    -               -                  -          FR16AS-12VARS  1SBN101035R1000  0.394
                                    To be completed with AS or ASL contactor, T16 thermal overload relay and MCB-10B (1SFA611610R2001) contact block.
                        1SBC133001V0014
         Empty enclosure
         with push-button
   823   824   825   826   827   828   829   830   831   832   833