Page 908 - ABB_Motor _Protection_and_Control_catalogue_20221216
P. 908

13/18            ABB  MOTOR PROTECTION AND CONTROL

          —

          DOL starters protected by MS165 manual motor starters
          With AF contactors - open type version in kit form






                 * For Ue>400V           127.6  5.02"   10  0.39"                 6  0.24"  10  35  1.38"  10
                          75  2.95"      95.5  3.76"
                *1.5  0.06" *1.5  0.06"                                            0.39"       0.39"
                                                                                                ø 4.6  0.18
                                     5.3                                                        M4  8-32 UNC
                                     0.21"
                               68.8  2.71”                                                      ø 8.6  0.34
                                     5.5
                                    0.22"




          290  11.42”  287.3  11.31”  151.9  5.98”  35 mm EN/IEC 60715            273.4  10.76"  268.4  10.57"  40  1.57"



                                 2X

                                    5.5
                                    0.22"
                                                                                                ø 4.2  0.17
                                                                                                M4  8-32 UNC
                                                                                                ø 6.4  0.25
                                                                                                M6  1/4-20 UNC
                               7  0.28"                                             5   45  1.77"  5
                  55  2.17"              111  4.37"   10  0.39"
             6  0.24"                                                             4.6  0.18"  0.2"  0.2"
          MS165
          + BEA65-4
          + AF40, AF52, AF65



                 * For Ue>400V           127.6  5.02"   10  0.39"
                          75  2.95"      95.5  3.76"
                *1.5  0.06" *1.5  0.06"
                             75  2.95"  5.5  0.22"  95.5  3.76"  10  0.39"
              * For Ue>400V
                                                    122.1  4.81"
           *1.5  0.06"  *1.5  0.06"  5.3
                                     0.21"
                               68.8  2.71”
                                    0.22"45.7  1.80" 5.5





          290  11.42”  288  11.34"  287.3  11.31”  287.3  11.31"  151.9  5.98”  35 mm EN/IEC 60715  195  7.68"  2x35mm EN/IEC60715



                                 2X                          10  0.39"
   13
                                    5.5
                                    0.22"
                                     (1)
                                         BPR65-4

                               7  0.28"  111  4.37"   10  0.39"
                  55  2.17"
             6  0.24"  6.5  0.26"  55  2.17"  6  0.24"  5.5  0.22"  105.5  4.15"
          MS165
          + BEA65-4
          + AF40, AF52, AF65 + BPR65-4

          Note: for Ue > 400 V, contactor lateral distance to grounded component 1.5 mm 0.06" min.
          (1) Assembly on fixed DIN Rails for DOL starter with BPR65-4 rail hook
          Main dimensions mm, inches
   903   904   905   906   907   908   909   910   911   912   913