Page 375 - Contactors_Catalogue
P. 375
ABB MOTOR CONTROL AND PROTECTION FOR ROLLING STOCK APPLICATIONS 7/5
—
Electrical, mechanical and
environmental requirements
The selected products from the Electronic Relays and Controls range fulfill the train construction requirements mentioned
on the previous pages. The following table shows which product of the range meets the requirements to which extent.
EN 50155
Voltage supply
Interrupts
S1 S2 C1 C2
no inter- interrup- 0.6 x U 0 x U Shock
Supply from Supply by a ruptions tions of up over n over n and Altitude Coated
accumulator static converter to 10 ms 100 ms 30 ms Tempera- vibration class EN PCB
Order code Type battery or a rotating set ture class EN 61373 50125-1 Board
Time relays
1SVR7x0030R3300 CT-MXS.22x 48 V DC ■ ■ ■ ■
1SVR7x0010R0200 CT-MFS.21x ■ ■ ■ -
1SVR7x0020R0200 CT-MVS.21x ■ ■ ■ - Cat. 1, AX max.
230 V AC / 50 Hz T3 5) no
1SVR7x0100R0300 CT-ERS.21x 24-110 V DC ■ ■ ■ - Class B 2000 m 1)
1SVR7x0180R0300 CT-APS.21x ■ ■ ■ -
1SVR7x0120R3300 CT-ARS.21x ■ ■ - n/a
Single-phase monitoring relays
1SVR7x0830R0300 CM-ESS.1x ■ ■ ■ -
1SVR7x0830R0400 CM-ESS.2x ■ ■ ■ -
1SVR7x0840R0200 CM-SRS.11x ■ ■ ■ - Cat. 1, AX max.
24-110 V DC 230 V AC / 50 Hz T3 5) no
1SVR7x0840R0400 CM-SRS.21x ■ ■ ■ - Class B 2000 m 1)
1SVR7x0840R0500 CM-SRS.22x ■ ■ ■ -
1SVR7x0840R0700 CM-SRS.M2x ■ ■ ■ -
Three-phase monitoring relays
1SVR7x0020R0200 CM-MPS.21x ■ ■ 2) 2)
1SVR7x0884R3300 CM-MPS.41x ■ ■ 2) 2)
1SVR7x0884R4300 CM-MPS.43x 3 x 400 V AC / ■ ■ 2) 2) Cat.1, AX max.
n/a 2) T3 5) no
1SVR7x0824R9300 CM-PFS.x 50 Hz 4) ■ ■ 2) 2) Class B 2000 m 1)
1SVR7x0794R1300 CM-PVS.31x ■ ■ 2) 2)
1SVR7x0794R3300 CM-PVS.41x ■ ■ 2) 2)
Insulation monitoring relays
1SVR7x0660R0100 CM-IWS.1x ■ ■ ■ ■
1SVR7x0670R0200 CM-IWS.2x 24-110 V DC 230 V AC / 50 Hz ■ ■ ■ ■
1SVR7x0660R0200 CM-IWN.1x ■ ■ - ■ Cat. 1, AX max.
1SVR7x0669R9400 CM-IVN.x n/a 3) n/a 3) n/a 3) n/a 3) n/a 3) n/a 3) T3 5) Class B 2000 m 1) no 07
1SVR7x0660R0200 CM-IWN.1x in
comb. with 24-110 V DC 230 V AC / 50 Hz ■ ■ - ■
1SVR7x0669R9400 CM-IVN.x
The insulation measurement of the devices is based on a figure of 2,000 m. The devices can be used in higher altitudes on request.
1)
Only applicable for devices with a DC power supply.
2)
passive device, no supply.
3)
self supplied from the measuring input.
4)
-25...+70 °C
5)
—
Order code and product type
Order code: 1SVR7x..... Product type: CM-IWN.1x
x: 3/5 = screw connection x: S = screw connection
x: 4/6 = Easy connect / push-in connection x: P = Easy connect / push-in connection