          Insulation monitoring relays

          Ordering details





                                    CM-range - Monitoring of unearthed supply systems
                                    The high reliability of a system is guaranteed by a continuous monitoring of the resistance
                                    between the system and the earth potential. An insulation monitoring of the CM-IWx range
                                    recognizes these so-called insulation faults and trips as soon as the measured value of the
                                    resistance between the system and earth potential falls below the set threshold. By using an
                                    insulation monitoring relay already the first insulation fault will be detected and can be fixed
                                    before a second fault occurs and forces the system to switch off.
                            2CDC 251 017 V0012  Choose between screw connection technology (double-chamber cage connection terminals)
                                    and the completely tool-free Easy Connect Technology (push-in terminals) with excellent vi-

          CM-IWS.2                  bration resistance.
                                    •  According to IEC/EN 61557-8
                                    •  Rated control supply voltage 24 - 240 V AC/DC

                                    CM-IWS
                                    •  For monitoring the insulation resistance of   •   Fault storage/latching configurable by
                                     unearthed systems: up to U  = 400 V AC  control input
                                                            n
                                    •  Superimposed DC signal             •  1 c/o (SPDT) contact, closed-circuit
                                    •  One measuring range 1–100 kW         principle
                                    •  Precise adjustment of the threshold value
                                     in 1 kW steps
                                    •  Interrupted wire detection

                                    Approvals / Marks:                      Classifications:
                                    A C D E K L / a, b                    EN 50155 (applicable parts),
                                                                          IEC 60571 (applicable parts), EN 45545-2

                                    —
                                    Ordering details - CM-IWS
                                    Rated    Nominal    System   Outputs   Adjustment    Type     Order code
                                    control   voltage    leakage ca-       range of the
                                    supply   U  of the   pacitance,        specified
                                              n
                                    voltage =   distribution   max.        response
                                    measuring  system to be                value R
                                                                                an
                                    voltage  monitored                     (threshold)
   07
                                    24-240    0-250 V AC /  10 μF          1-100 kW     CM-IWS.1S  1SVR730660R0100
                                    V AC/DC  0-300 V DC          1 c/o (SPDT)           CM-IWS.1P  1SVR740660R0100
                                                                 contact
                                    24-240                                              CM-IWS.2S  1SVR730670R0200
                                    V AC/DC  0-400 V AC   10 μF            1-100 kW     CM-IWS.2P  1SVR740670R0200