7/8              ABB  MOTOR CONTROL AND PROTECTION FOR ROLLING STOCK APPLICATIONS

          —

          Single-phase monitoring relays

          Ordering details





                                    CM-range - Current and voltage monitoring relays
                                    Single-phase voltage and current monitoring relays protect sensitive equipment and control
                                    systems against undervoltage (brownout) or undercurrent events or overvoltage or overcur-
                                    rent events. Different units with adjustable or fixed threshold values (trip points) are
                                    available.
                                    All devices are available with two different terminal versions. Choose between screw connec-
                                    tion technology (double-chamber cage connection terminals) and the completely tool-free
                             2CDC 251 054 V0011  Easy Connect Technology (push-in terminals) with excellent vibration resistance.

                                    •  Monitoring of DC and AC currents (3 mA to 15 A)
          CM-SRS.22S                •  Monitoring of DC and AC voltages (3-600 V)
                                    •  TRMS measuring principle
                                    •  One device includes 3 measuring ranges
                                    •  Over- and/or undercurrent/voltage monitoring configurable  1)
                                    •  CM-SRS.M: Latching function configurable
                                    •  Hysteresis adjustable (3-30 %) or fixed hysteresis (5 %)  1)
                                    •  Precise adjustment by front-face operating controls
                                    •  Latching function configurable  1)  1)
                                    •  Start-up delay T  adjustable: 0; 0.1 - 30 s
                             2CDC 251 060 V0011  •  Tripping delay T  adjustable: 0; 0.1 - 30 s  1)
                                                  v
                                                  v
                                    •  22.5 mm width
                                    •  Approvals / Marks:  A C D K E L / a b
          CM-ESS.MP                 •  3 LEDs for status indication
                                    •  Classifications: EN 50155 (applicable parts), IEC 60571 (applicable parts), EN 45545-2

                                    1)  depending on device


          b Overcurrent monitoring  —
          a Undercurrent moni-      Ordering details
            toring                  Rated control   Function   Tripping   Outputs  Measuring   Type *  Order code
          e Without latching        supply voltage  configurable  delay T  range
          f With latching                                      V
                                                                    1 c/o              CM-SRS.11S  1SVR730840R0200
                                                   b
                                    24-240 V AC/DC        without   (SPDT)
                                                   a                       3-30 mA     CM-SRS.11P  1SVR740840R0200
                                                                    contact  10-100 mA
                                                                    2 c/o              CM-SRS.21S  1SVR730840R0400
   07
                                                   b      adjustable       0.1-1 A
                                    24-240 V AC/DC                  (SPDT)
                                                   a      0 or 0.1-30 s                CM-SRS.21P  1SVR740840R0400
                                                                    contacts
                                                   b
                                    24-240 V AC/DC                                     CM-SRS.22S  1SVR730840R0500
                                                   a                2 c/o   0.3-1.5 A
                                                   b      adjustable    (SPDT)   1-5 A
                                    24-240 V AC/DC  e     0 or 0.1-30 s  contacts  3-15 A  CM-SRS.M2S  1SVR730840R0700
                                                   a
                                                   f
                                    24-240 V AC/DC                  1 c/o   3-30 V     CM-ESS.1S  1SVR730830R0300
                                                   d      without   (SPDT)   6-60 V
                                                   c                       30-300 V
                                    24-240 V AC/DC                  contact            CM-ESS.1P  1SVR740830R0300
                                                                           60-600 V
                                                                           3-30 V
                                    24-240 V AC/DC                  2 c/o              CM-ESS.2S  1SVR730830R0400
                                                   d      adjustable    (SPDT)   6-60 V
                                    24-240 V AC/DC  c     0 or 0.1-30 s  contacts  30-300 V   CM-ESS.2P  1SVR740830R0400
                                                                           60-600 V