          Insulation monitoring relays

          Ordering details





                                    CM-IWN.1
                                    •  For monitoring the insulation resistance of unearthed systems up to U = 250 V AC and
                                                                                               n
                                     300 V DC or U = 400 V AC and 600 V DC
                                                n
                                    •  Prognostic measuring principle with superimposed square wave signal
                                    •  One or two measuring ranges
                                        - 1-100 kW
                                        - 1-100 kW + 2-200 kW
                                2CDC 251 020 V0012  •  One or two configurable c/o contacts
                                    •  Precise adjustment of the measuring value in 1 or 2 kW steps
                                    •  (Non-volatile) fault storage, configurable latching, interrupted wire protection, open- or
          CM-IWN.1                   closed-circuit principle selectable
























                                    —
                                    Ordering details - CM-IWN
                                    Rated    Nominal    System    Outputs   Adjustment    Type    Order code
                                    control   voltage    leakage ca-        range of the
                                    supply   U  of the   pacitance,         specified
                                              n
                                    voltage =   distribution   max.         response
                                    measuring  system to be                 value R
                                                                                 an
                                    voltage  monitored                      (threshold)
                                                                                                                      07
                                             0-400 V AC /         2 x 1 or    1-100 kW
                                             0-600 V DC           1 x 2 c/o   2-200 kW   CM-IWN.1S  1SVR750660R0200
                                    24-240    Expendable   20 μF  (SPDT)    (activated / de-
                                    V AC/DC
                                             with coupling        contacts   activated by
                                             unit CM-IVN.x        configurable DIP-switch)  CM-IWN.1P  1SVR760660R0200
                                    —
                                    Ordering details - Coupling unit expansion for CM-IWN.xS/P
                                    Rated control supply voltage =  Nominal voltage  Un of the distribution   Type *  Order code
                                    measuring voltage     system to be monitored
                                    Passive device, no control    0-690 V AC /          CM-IVN.S  1SVR750669R9400
                                    supply voltage needed  0-1000 V DC                  CM-IVN.P  1SVR760669R9400

                                    * S: screw connection
                                       P: push-in / easy connect