Page 9 - Contactors_Catalogue
P. 9

ABB  MOTOR CONTROL AND PROTECTION FOR ROLLING STOCK APPLICATIONS                  1/7
                                                                                                                      01
          —

          Freedom of movement

          Even under the most extreme conditions




          Always on the go in heat, cold, humidity – the environmental conditions for rolling

          stock are usually much more extreme than those for industrial facilities. All rolling
          stock products are tested and documented on the basis of safety standards.









          Climatic conditions                                 Mechanical conditions
          A key factor is the changing climatic conditions. All devices   Resistance to shock and vibrations is essential. All the cable
          used in rolling stock must prove that they can continue to   connections must be completely tight, and no screw connec-
          perform when there are major temperature variations or a   tion may slacken due to vibrations. The vibration resistant
          rapid temperature increase. Humidity limit values set high   Push-in Spring terminals, as offered by ABB are highly effica-
          standards, so that no failures occur, particularly in tunnels.   cious here.






          Electrical conditions                               Easy Connect technology Push-in Spring terminals
          Voltage variations are common in rail travel. They range   Several types of terminals are available to connect cables
          from roughly -30 % to +25 % of the rated voltage and can be   with standard ferrules or ring tongue ferrules in regards
          the cause of major damage. All the electrical components   with material design requirements.
          used in the train must provide prior proof that they can work   In case of standard ferrule use, Push-in Spring terminals
          safely within this range.                           2-in-1 connection allows to use ferruled and rigid cables
          However, interference emissions from cables or radiation   (Push-in mode) or cables without ferrule (Spring mode)
          can also impair the function of the electronic devices. Before   in the same terminal. In Push-in mode, cables can be inserted
          the devices can be used in rail applications, they must,   by just simply pushing them in by hand.
          among other things, prove their electromagnetic compati-  For de-wiring, only one screwdriver size is needed for the
          bility according to the testing and measuring principles, to   entire range. No twisting or turning is required avoiding
          show that they do not cause any high frequency fault above   damages to the terminals and to your installation as a whole.
          a specified value.                                  Push-in Spring terminals are completely secure, making your
                                                              equipment the perfect solution for environments with high
                                                              levels of vibrations.
   4   5   6   7   8   9   10   11   12   13   14