Technical equipment and server rooms

 Servers, fire alarm systems, fire extinguishing systems, UPS,

 air-conditioning and cooling systems

                8
 Effective room shielding and a coherent surge protection   alarm systems, as well as air-conditioning and cooling   9
 concept based on the lightning protection zone concept for   systems. To ensure safe and uninterrupted operation, all
 power supply and communication lines prevent the loss of   components must be protected against surges and their
 sensitive data and ensure safe operation of online systems in   consequences. Possible protection measures to reduce the
 case of lightning strikes and surges.   failure of electrical and electronic systems in a building are
 described, for example, in IEC 62305-4.
 Today, digitally networked technologies are increasingly
 determining the quality of life and social participation in all   A combination of earthing, equipotential bonding, spatial
 sections of the population and will continue to do so in the   shielding, cable routing / shielding, and installation of
 future. In this context, a needs-based data infrastructure is   coordinated surge arresters provides reliable protection
 the basic prerequisite for modern buildings. But, at the same   against failures.
 time, networking also means that the failure of individual,   Due to its central importance, we recommend treating the
 central components can bring the entire system to a   server room as lightning protection zone 2 and designing it   1-7
 standstill.
 as a Faraday cage. In addition, all incoming and outgoing
 In addition to server equipment, the infrastructure of server   electrical lines should be protected by installing surge
 rooms includes other systems designed to ensure safety and   arresters.
 continuous operation such as UPS, fire extinguishing and   Surge protection  Application / interface  Type  Part No.

 IT area     1                    DEHNguard M ACI FM           Power supply           DG M TNS ACI 275 FM 952 440
 LPZ 1                            Modular surge arrester for TN systems   UPS system 230/400 V
                                  with integrated ACI technology.
 Technical support area  LPZ 2  subscriber connection
 e.g. RJ45 socket

 cooling /                        DEHNcord 3P TT 275 FM        Protection of terminal devices   DCOR 3P TT 275 FM  900 439
 air-conditioning supply  ≥ 10 m  2  Compact three-phase arrester for all   230/400 V
                                  installation systems. Mounted on DIN   (measuring and control
                                  rails or, in confined spaces, using screw   systems)
 LPZ 3                            lugs.
 fire / hazard alarm
 technology  3                    DEHNpatch Class E            Server / network       DPA M CLE RJ45B 48 929 121
 rack server                      Universal arrester for Industrial Ether-
                                  net, PoE+.
 safety technology
 (access control,
 video surveillance,              Mounting set DEHNpatch       Server / network       MS DPA          929 199
 alarm systems)  rack server  4   For mounting DEHNpatch in 19“ data
                                  cabinets.

             5                    SFL Protector                Protection of terminal devices   SFL PRO 6X 19“  909 251
                                  Multiple socket outlet with integrated   230 V
 UPS  rack server                 surge protection and mains filter for   (server racks)
                                  data cabinets.
 CP IT
 (campus distributor   6          BLITZDUCTORconnect           Measuring and control data   BCO ML2 BD HF 5  927 271
  for infomation                  Space-saving, modular combined arres-  lines
 select main distribution board  rack server  technology)  ter with a width of 6 mm and push-in
                                  connection technology.

 building    7                    BUStector BT 24              KNX bus systems        BT 24           925 001
 Power supply  fire protection dampers  distributor  Surge arrester with minimal space
                                  requirements, can be easily plugged
 Copper-based   NT / SEP          onto, e.g., a bus coupler instead of a
 cabling                          standard bus terminal.
 Fibre optic cable
             Equipotential bonding / shielding                                                        Part No.
             8                    Mesh mat                                                            618 214
                                  EMC shielding measures possible, mounted in ceilings and walls.


 Use our online configurators   More information at:    9  Connecting clamp for mesh mats             540 271
 for easy and fast selection  de.hn/configurators  For interconnecting mesh mats / connecting mesh mats to equipotential bonding systems.



 10                                                                                                               11
   6   7   8   9   10   11   12   13   14   15   16