8/14             ELECTRICAL INSTALL ATION SOLUTIONS FOR BUILDINGS   2CHC 420 001 C0201




          —
          Energy efficiency
          Energy meters. The details make the difference.




         A series                           B series                           C series
         Key applications                   Key applications                   Key applications
           • Facility management installations  • Cost transfer/billing          • HVAC applications
           • Critical power                   • Solar power                      • Stand-alone applications
           • Production lines                 • EV chargers                      • Domestic applications
           • System solutions                 • Elevators/escalators             • Camping and Marinas
           • Power quality                    • Lighting                         • Etc.
           • Etc.                             • Installation beside machines
                                              • Etc.                           Key performance
         Key performance                                                       Single phase or three phase
         Single phase or three phase        Key performance                    Very compact
         Direct connected up to 80 A or     Single phase or three phase          • 1 & 3 modules.
         transformer current- and/or voltage   Direct connected up to 65 A or CT   Direct connected up to 40 A
         transformers (CTVT)                connected (three phase types)      Active energy measurement
         Active energy measurement          Active energy measurement          Accuracy class 1
  8
           • Class B (Cl. 1) or               • Class B (Cl. 1) or             Alarm functions
           • Class C (Cl. 0,5 S) on CTVT      • Class C (Cl. 0,5 S) on CT connected   MID (Module B and F) as option
            connected meters                   meters                          Pulse output (S0 compatible)
         Wide voltage range                 Alarm functions                    Instrumentation
           • 100 - 690 V phase to phase     MID (Module B and D)               The C series meters support reading
           • 57,7 - 400 V phase to neutral  Reactive energy measurement        of instrument values. A number of
         Alarm functions                    Import/export measurement of energy  electrical properties can be read:
         MID (Module B and D)                 • Optional communication via via   • Power factor
         Reactive energy measurement           M-Bus or                          • Active power
         Import/export measurement of energy  • RS-485 (For Modbus RTU or EQ     • Current
         Optional communication                bus)                              • Voltage
           • via M-Bus or                   4 tariffs controlled by
           • RS-485 (For Modbus RTU or EQ     • input or
            bus)                              • communication
         4 tariffs controlled by inputs,    Pulse outputs (S0 compatible)
           • communication or
           • built-in clock                 Instrumentation
         Previous values by                 The B series meters support reading of
           • day or                         instrument values.
           • week or                        A large number of electrical properties
           • month                          can be read. Depending on version of
         Demand measurement (per period)    the meter the following data is
           • 3 maximum                      available:
           • 1 minimum                        • Active power
         Load profiles                        • Apparent power
           • 8 channels independently         • Reactive power
            configurable                      • Current
           • 40 000 values total              • Voltage
         Harmonics measurement up to 16       • Frequency
                                     th
         harmonic                             • Power factor
           • Current
           • Voltage
           • and evaluation of THD
         Pulse outputs (S0 compatible)

         Instrumentation
         The A series meters support reading of
         instrument values. A large number of
         electrical properties can be read.
         Depending on version of the meter the
         following data is available:
           • Active power
           • Apparent power
           • Reactive power
           • Current
           • Voltage
           • Frequency
           • Power factor
           • Harmonics (Current and Voltage)
           • Total harmonic distortion