          Energy efficiency
          Selection guide EQ meters.




         How do I select the best meter for my application?
         There are many versions of EQ meters in order to meet your requests. The EQ program comprises meters with different
         functionalities such as tariffs, communication interfaces or advanced clock functions. Spend a little time to evaluate
         the functions and imagine how they could add extra value to your metering. For example, the input counter (from Silver
         level) on an EQ meter can be used to count products produced by a machine and be read out together with the energy
         consumption of the same machine. In one easy go you can allocate energy to any produced product from one source.
         Another  useful function is previous values (from Gold level). If you charge users in intervals the meter can secure the data
         even in the event of a broken communication link. You can collect the correct interval data later and also make it visible for
         your counterpart immediately on the meters display in case of any discussions.




                                                                                                                       8













                                        Single phase                   Three phase
         Function
                                        C11    B21     A41     A42     C13     B23     B24     A43     A44
         Direct connected                1     1   3   1  3  4          1       1  2  3         1  2  3  5
         Transformer connected                                 1    3  5                1  2  3         1  2  3  4  5
         2 element metering                                                     1  2  3  1  2  3  1  2  3  5  1  2  3  4  5
         3 element metering                                             1       1  2  3  1  2  3  1  2  3  5  1  2  3  4  5

         Accuracy 1 %, Class 1, Class B  1     1   3   1  3  4  1  3    1       1  2  3  1  2   1  2  3  5  1  2  3
         Accuracy 0.5 %, Class 0,5 S, Class C                         5                    3               3  4  5
         Active energy                   1     1   3   1  3  4  1  3  5  1      1  2  3  1  2  3  1  2  3  5  1  2  3  4  5
         Reactive energy                           3      3  4     3  5          2  3    2  3    2  3  5  2  3  4  5
         Apparent energy                           3      3  4     3  5          2  3    2  3    2  3  5  2  3  4  5
         Import/Export energy                      3      3  4     3  5          2  3    2  3    2  3  5  2  3  4  5
         Tariff registers, 1-4                     3      3  4     3  5            3       3       3  5    3  4  5
         Instrument values               1     1   3   1  3  4  1  3  5  1      1  2  3  1  2  3  1  2  3  5  1  2  3  4  5
         Alarm function                  1     1   3   1  3  4  1  3  5  1      1  2  3  1  2  3  1  2  3  5  1  2  3  4  5
         Harmonics, 2th-16th and THD                                  5                               5       5
         Previous values - day, week, month                 4         5                               5      4  5
         Max and min demand                                 4         5                               5      4  5
         Load profiles - 8 channels                                   5                               5       5
         Pulse output                    1     1       1       1        1       1  2    1  2    1  2    1  2
         I/O board - 2 in, 2 out                   3      3  4     3               3       3       3       3  4
         Configurable I/O - 4 I/O channels                            5                               5        5
         Tariffs controlled by input               3      3  4     3  5            3       3       3  5    3  4  5
         Tariffs controlled by communication       3      3  4     3  5            3       3       3  5    3  4  5
         Tariffs controlled by clock                        4         5                               5      4  5
         MID approved, verified          optional  1  3  1  3  4  1  3  5  optional  1  2  3  1  2  3  1  2  3  5  1  2  3  4  5
         IEC approved                    1     1   3   1  3  4  1  3  5  1      1  2  3  1  2  3  1  2  3  5  1  2  3  4  5
         Communication - Infrared (M-Bus)      1   3   1  3  4  1  3  5         1  2  3  1  2  3  1  2  3  5  1  2  3  4  5
         Communication - M-Bus                  optional  optional  optional    optional  optional  optional  optional
         Communication - RS-485 Modbus          optional  optional  optional    optional  optional  optional  optional
         Communication - RS-485 EQ bus          optional  optional  optional    optional  optional  optional  optional
          1  = Steel       3  = Silver       5  = Platinum    Optional = Available
          2  = Bronze      4  = Gold           = Not available  on some order codes
   750   751   752   753   754   755   756   757   758   759   760