Page 835 - Din prodcuts 2020
P. 835
9/5
—
SMISSLINE TP plug-in system
MCBs S 400 series
S400M and S400 UC
General Data IEC/EN 60898-1 S400 B,C,D,K°, IEC/EN 60947-2 S400 C,K,UCC, UCK
Poles 1P, 1P+NP, 2P, 3P, 3P+NP
Tripping characteristics B,C,D,K, UCC, UCZ
Rated current In A 0.5 … 63
Rated frequency f Hz 50/60 Hz ( 162/3 on request)
Rated insulation voltage Ui acc. to DIN EN V 400 VAC
60664-1
Rated impulse withstand voltage Uimp. kV 4 kV
(1.2/50 µs)
Overvoltage category III
Pollution degree 2
Data acc. to IEC/ Rated operational voltage Ue V 1P: 230/400 V AC; 1P+N: 230 V AC ; 2...4P: 400 V AC; 3P+N: 400 V AC
EN 60898-1 Max. power frequency recovery voltage (Umax) V 1P: 253 V AC; 1P+N: 253 V AC; 2P: 440 V AC; 3...4P: 440 V AC; 3P+N:
440 V AC; 1P: 72 V DC; 2P: 125 V DC
Rated short-circuit capacity Icn kA 6 kA S400E
10 kA S400M
Energy limiting class 3
Reference temperature for tripping °C C, D: 30 °C 9
characteristics
Electrical and Mechanical Endurance ops. 10 000 ops.
Data acc. to IEC/ Max. power frequency recovery voltage (Umax) V 254/440 V AC 1P: 60 V DC 2P: 125 V DC for S400M
EN 60947-2 1P: 125 V DC 2P: 250 V DC for S400 UCC and UCZ
Rated ultimate short-circuit capacity Icu kA 25 kA (0,5 up to 16 A, 240/415 V)0,5 to 2 A 50 kA on request
15 kA (20 up to 63 A, 240/415 V)
15 kA (0,5 up to 16 A, 254/440 V)
6 kA (20 up to 63 A, 254/440 V)
S400UC: 10 kA (0,5.63A, 220 V d.c. 1pole)
S400UC: 20 kA (0,5.63A, 110 V d.c. 1pole)
S400UC: 25 kA (0,5.63A, 220 V d.c. 2pole)
S400UC: 10 kA (0,5.63A, 440 V d.c. 2pole)
S400UC: 10 kA (0,5.63A, 230/400 V)
Rated service short-circuit capacity Ics kA 15 kA (0,5 up to 16 A, 240/415 V)
7,5 kA (20 up to 63 A, 240/415 V)
6 kA (0,5 up to 16 A, 254/440 V)
3 kA (20 up to 63 A, 254/440 V
S400UC: 10 kA (0,5.63A, 220 V d.c. 1pole)
S400UC: 10 kA (0,5.63A, 110 V d.c. 1pole)
S400UC: 20 kA (0,5.63A, 220 V d.c. 2pole)
S400UC: 10 kA (0,5.63A, 440 V d.c. 2pole)
S400UC: 6 kA (0,5.63A, 230/400 V)
Dielectric test voltage kV
Reference temperature for tripping °C C: 30 °C K: 40 °C
characteristics
Electrical and Mechanical Endurance ops. In < 32 A: 20 000 operating cycles
In ≥ 32 A: 10 000 operating cycles
Mechanical Data Housing Insulation group I, RAL 7035
Toggle Insulation group II, black, sealable
Classification acc. To NF F 126-101, NF F 16-102
Protection degree acc. to EN 60529 IP20*, IP40 in enclosure with cover
Mechanical endurance ops. 20 000 ops.
Shock resistance acc. to IEC/EN 60068-2-30
Vibration resistance acc. to IEC/EN 60068-2-6 5 g – 20 cycles at 5 … 150 … 5 Hz with load 0.8 In
Environmental conditions (damp heat)
acc. to IEC/EN 60068-2-30 °C/RH 28 cycles with 55 °C/90–96 % and 25 °C/95–100 %
Ambient temperature °C –25 … +55 °C
Storage temperature °C –40 … +70 °C
Installation Standed Cross-section of conductors (top/ mm 2 top 0.75–25 mm2/bottom no terminal pluggable MCB
bottom)
Flexible Cross-section of conductors (top/ mm 2
bottom)
Tightening torque Nm in-Ibs. 2.8 Nm
Screwdriver No. 2 Pozidrive
Mounting plug in on bus bar system SMISSLINE
Mounting position any
Supply any
Dimensions and Mounting dimensions acc. to DIN 43880
weight Pole dimensions (H x D x W) mm 91x18x82
Pole weight g 110