Example with external lightning protection up and running
Lightning and surge protection solutions
A A
B Whether modern work stations, office buildings or commercial premises – they all require
G reliable technical components to fulfil their function. Outages must be prevented.
G C
Modern work environments are becoming increasingly sensitive
Buildings are becoming smart. They are based on networked technical components
L K which require a permanent supply of power and data. Today modern commercial
F buildings such as hotels, medical facilities or office buildings are defined by smart
building equipment. As an example, intelligent systems automatically control and
D optimise the energy requirement, arrange for the cleaning of only those areas which
have really been used and control access via sensitive security technology.
E H Failure of individual components, e.g., following lightning strikes and surges, may
I J cause the collapse of all networked systems, bringing entire buildings and work
environments to a standstill, access control cannot be assured – these horror
scenarios can be avoided! Lightning and surge protection precautions ensure that
important technology always works safely and reliably.
Regulations call for protection measures
External lightning protection
The surge protection requirements of the IEC 60364-4-44 clause 443 and
A Air-termination system B Roof conductor holder C Down conductor D Terminal lug IEC 60364-5-53 clause 534 standards mentioned before also apply to office and
for flat roofs commercial buildings. As far as the protection of people is concerned, further build-
ing regulations must be observed, e.g., fire protection regulations. Here, lightning
and surge protection also makes a significant contribution towards preventing people
from sustaining serious injuries and buildings from catching fire.
Self-supporting air-termi- Conductor holder with Round wire, Al, 8 mm Round wire, stainless steel If medical premises such as diagnosis rooms with MRT or X-ray devices, dental surgeries
nation rod with tripod concrete base (V4A), 10 mm or day surgery centres are located in commercial buildings, IEC 60364-7-710 also
applies. The focus here is on the safety of patients and medical staff. The standard
Part No. 105 530 Part No. 253 050 Part No. 840 028 Part No. 860 115
specifies requirements for electrical safety and the uninterrupted power supply in
Surge protection – Power supply (Red/Line) these areas.
E Main distribution board F Sub-distribution board G Protection of terminal devices H Photovoltaics
DEHNventil M TNS DEHNguard TNS ACI DEHNflex DEHNcube YPV SCI 1)
Find out about further protection measures:
Part No. 951 405 Part No. 952 440 Part No. 924 396 Part No. 900 910
Surge protection – Data and information technology (Yellow/Line)
I Data technology J LSA system K Ethernet, PoE++ L KNX / EIB bus
External lightning protection Photovoltaics E-mobility Technical building
BLITZDUCTOR BD 24 DEHNrapid LSA DEHNpatch outdoor BUStector services equipment
Part No. 920 300 / 920 344 Part No. 907 401 / 907 498 / 907 430 Part No. 929 221 Part No. 925 001 Page 08 | 09 Page 18 Page 19 Page 21
For functional or residential buildings above 100/ 200 m, so called High Rise Buildings please feel free to contact us at [email protected]
or get in touch with your local DEHN partner.
12 1) In case of external protection and not kept sepration distances a type 1 arrester e.g. DEHN combo YPV 1200 is required 13