Page 15 - DS225 Modern-buildings
P. 15

Find out more at:
                                                                                                  www.de.hn/industry
 Industry   Keeping production rolling

 Examples with HVI Lightning Protection  Lightning and surge protection solutions





            Lightning and surge protection concepts ensure that the sensitive networked
            automation systems of Industry 4.0 are protected, and that plants and production
            processes are permanently available..



 D          Keeping production rolling
 B  C  J  G  Trouble-free communication of machines and plants in modern production environ-
 A          ments requires the consistent flow of both power and information.
 K          Machines must run reliably and work processes function smoothly – even in case of
            thunderstorms and surges. A production outage can have severe, sometimes even
            existential,  financial  consequences.  Environmental  issues  may  occure.  Risks  easily
 H  H  E    avoided by a carefully planned lightning protection concept.







 I  L  F    Considering power and data technology
 G          For industrial companies, it is advisable to install an isolated external lightning pro-

            tection system. Separation distances are reliably maintained, and lightning energies
            safely discharged along the outside of the building. This prevents sensitive electric
            components inside the building from disturbance and destruction.

            Combining external lightning protection with internal protection provides additional
            protection. Protective devices such as ACI or CI arresters secure the power supply
 External lightning protection – HVI Lightning Protection  and, at the same time, save valuable space. Since these arresters do not require a
            backup fuse, errors when dimensioning an upstream fuse are automatically excluded.
 A  Air-termination system  B  Air-termination system  C  Down conductor  D  Down conductor  It is also easier to keep connecting cables within the prescribed lengths.

            In addition to the power supply, data lines are an important lifeline of modern
            production plants. Data exchange and networked communication structures are the
            core components of Industry 4.0. Therefore, all data networks must be protected against dangerous surges. The main issue
 Tripod with concrete base  Supporting tube with   HVI long Conductor  Conductor holder with    here is to choose adequate data and information technology arresters for the relevant system – i.e. ones which are compatible
 air-termination rod  tensioning strap  with bus systems such as KNX, DALI.
 Part No. 105 351 / 102 010  Part No. 105 325  Part No. 819 131  Part No. 275 320
 Surge protection – power supply (Red/Line)
 E  Transformer substation  F  Low-voltage main    G  Sub-distribution board  H  Protection of terminal
 distribution board  devices





 DEHNvenCI 1 255 FM  DEHNventil M TNS 255 FM  DEHNguard M TNS ACI 275  DEHNflex
 Part No. 961 205  Part No. 951 405  Part No. 952 440  Part No. 924 396  Find out about further protection measures:
 Surge protection – data and information technology (Yellow/Line)

 I  Data technology  J  Public address systems  K  Ethernet, PoE++  L  KNX / EIB bus




             External lightning protection  Alarm / security      LED lights           Technical building
 BLITZDUCTOR BE 24  DEHNvario 2 BY S 150 FM  DEHNpatch RJ45B 48  BUStector   systems   services equipment
 Part No. 920 300 / 920 324  Part No. 928 430  Part No. 929 121  Part No. 925 001  Page 08  | 09  Page 16  | 17  Page 20  Page 21


 14                                                                                                                 15