Page 19 - Ferraz semiconductor UL
P. 19
Semiconductor (A) fuses
Semiconductor (AC) fuses
American Round Fuses
Form 101 Range
A60Q
Semiconductor Protection Fuses
2
2
I t at 600VDC, I t at 600VAC, Watts Loss Data
100kA, L/R = 10 ms 100kA
2
2
2
Ampere Clearing I t Ampere Melting I t Clearing I t Ampere Watts Loss @ Watts Loss @
Rating (A s) Rating (A s) (A s) Rating 80% Rating (W) 100%Rating (W)
2
2
2
5 40 5 5 60 5 0.5 0.7
8 42 8 6.5 70 8 0.7 1.1
10 70 10 10 110 10 0.9 1.5
12 90 12 17 150 12 1.3 2.0
15 110 15 26 180 15 1.9 3.0
20 200 20 41 330 20 2.6 4.4
25 260 25 69 440 25 2.9 5.3
30 520 30 132 860 30 3.0 5.8
35 780 35 197 1300 35 3.3 6.4
40 1100 40 276 1800 40 3.6 7.0
5 to 40A
Melting Time –
Current Data, 600V Fuses
Standard Fuse Ampere ratings,
catalog and reference Numbers
Ampere Catalog Reference Ampere Catalog Reference
Rating Number Number Rating Number Number
5 A60Q5-2 E217400 20 A60Q20-2 B214338
6 A60Q5-2 E217400 25 A60Q25-2 Z214842
8 A60Q8-2 T218425 30 A60Q30-2 E215859
10 A60Q10-2 Z212289 35 A60Q35-2 J216369
12 A60Q12-2 M212807 40 A60Q40-2 E218879
15 A60Q15-2 X213322
TIME IN SECONDS Peak Let-Thru Current Data
For ampere ratings and styles not listed, ask sales agent
– 5 to 40A, 600 Volts AC
MAX. INSTANTANEOUS PEAK LET-THRU AMPERES
AVAILABLE CURRENT IN RMS SYMMETRICAL AMPERES
CURRENT IN AMPERES
SCAC19
12/04