Page 19 - IDEC timer catalogue
P. 19

Timers                                                                            GT3A Series


        GT3A-4 Timing Diagrams
        Delayed DPDT
                                 (A Type)
                                 (Contact Input)             (Transistor Input)      (B Type)

                                             n  o  p                     n o  p       Start  Reset  n o p              Switches & Pilot Lights
         Operation                         m         q   Reset  Start  Gate  m  q           m         q
         Mode Selection           Reset Start  Gate
                                           l         r                l          r          l         r
                                            k        s                 k        s           k         s
                                         (-)            (+)          (-)            (+)   (-)            (+)
                                              j                          j                    j
                                               POWER                      POWER                 POWER
                           Item  Terminal Number                             Operation
                          Power  2 - 10 POWER
                                   2 - 6 (A)
         ON-Delay 2            Start  5 - 7 (B)  ON or L                                                               Display Lights
                                   2 - 7 (A)
                          Input  Reset  ON or L
               MODE                6 - 7 (B)
                               Gate  2 - 5 (A)  ON or L
                A                 1 - 4
                          Delayed   8 - 11  (NC)
                          Contact  1 - 3
                                  9 - 11  (NO)
                               POWER
                          Indicator
                               OUT
                          Set Time
                                                T                  Ta             T'           T"
                           Item  Terminal Number                             Operation
                          Power  2 - 10 POWER                                                                          Relays & Sockets
                                   2 - 6 (A)
         Cycle 2               Start  5 - 7 (B)  ON or L
                                   2 - 7 (A)
                          Input  Reset  ON or L
               MODE                6 - 7 (B)
                               Gate  2 - 5 (A)  ON or L
                B                 1 - 4
                          Delayed   8 - 11  (NC)
                          Contact  1 - 3
                                  9 - 11  (NO)
                               POWER
                          Indicator
                               OUT
                          Set Time
                                              T  T  T  T  T  T  T  Ta        T   T  T  T"        T"  T  T  T  T  T     Timers
                           Item  Terminal Number                             Operation
                          Power  2 - 10 POWER
                                   2 - 6 (A)
         Signal ON/OFF-Delay 1  Start  5 - 7 (B)  ON or L
                                   2 - 7 (A)
                          Input  Reset  ON or L
               MODE                6 - 7 (B)
                               Gate  2 - 5 (A)  ON or L
                C                 1 - 4
                          Delayed   8 - 11  (NC)
                          Contact  1 - 3
                                  9 - 11  (NO)
                               POWER
                          Indicator
                               OUT                                                                                     Terminal Blocks
                          Set Time
                                              T       T      Ta      T      Ta     T    T     T         T"      Ta
                           Item  Terminal Number                             Operation
                          Power  2 - 10 POWER
                                   2 - 6 (A)
         Signal OFF-Delay 1    Start  5 - 7 (B)  ON or L
                                   2 - 7 (A)
                          Input  Reset  ON or L
               MODE                6 - 7 (B)
                               Gate  2 - 5 (A)  ON or L
                D                 1 - 4
                          Delayed   8 - 11  (NC)
                          Contact  1 - 3
                                  9 - 11  (NO)
                               POWER                                                                                    Circuit Breakers
                          Indicator
                               OUT
                          Set Time
                                                 T           Ta             Ta     T            T              T

             T = Set time  Ta = Shorter than set time
             T = T' + T"
                                            USA: 800-262-IDEC          Canada: 888-317-IDEC                        809
   14   15   16   17   18   19   20   21   22   23   24