Timers                                                                            GT3D Series


                                         Instructions:  Setting GT3D-2, GT3D-3 Timers


                               Timed OUT Indicator


                               Digital Time Display                            m Time Setting                          Switches & Pilot Lights
                               (LCD backlit with red LED)
                                                                                 Digital Switch



                             j Indication Mode Selector                        l Time Range Selector
                                 1     1                                         9.99S – 99.9H


                                                         k One-Shot Time Selector                                      Display Lights
                                                          A, B, C, D

              Step 1                     Desired Mode/Selection                             Remarks
                         Time Display   j Indicator Mode   Operation Mode  k Operation
                           Mode        Selector                Mode Selector

                         Time elapsed    1                    A
                                                    ON-delay 1     A       1. Use the fl at screwdriver to set the selectors. Since selectors do not
                         Time remaining  1                                 turn all the way around, both clockwise and counterclockwise rotation
                                                                           may be necessary.                           Relays & Sockets
                         Time elapsed    1                    B
         Select the desired time                     Interval      B       2. The j Indicator Mode Selector determines whether the Digital
                                                                           Time Display shows the time elapsed or time remaining. The k
         display and operation   Time remaining  1                         Operation Mode Selector determines the desired operation mode.
         modes.
                                                                           Decide which display and mode is desired, then use these two selec-
                         Time elapsed    1                    C            tors jk to set the operation mode.
                                                     Cycle 1       C
                         Time remaining  1                                 3. The j Operation Mode Selector has two blank modes which are
                                                                           not intended for use. Always have this selector set to A, B, C, or D.
                         Time elapsed    1                    D
                                                     Cycle 3       D                                                   Timers
                         Time remaining  1
              Step 2          Desired Operation           Selection                         Remarks
                                                      l Time Range Selector
                              Base Time Ranges     Decimal Point   Time Increment   1. The l Time Range Selector controls both the decimal point indica-
                                                    Indicator    Indicator
                                                                           tor (9.99, 99.9, 999) and the time increment indicators S (seconds), M
                            0.01 seconds to 9.99 seconds  9.99             (minutes), and H (hours).
         Select a time range   0.1 seconds to 99.9 seconds  99.9   S       2. Chose which base time range contains the targeted timer setting.
         that contains the                                                 Then use the l Time Range Selector to set the decimal point indica-
         desired period of time.  1 second to 999 seconds  999             tor and time increment indicator to its corresponding pair of settings.  Terminal Blocks
                            0.1 minutes to 99.9 minutes  99.9              3. Since these confi gurations offer a complete range of settings from
                                                                   M
                             1 minute to 999 minutes  999                  0.01 seconds to 99.9 hours, the setting of 9.99 for minutes and the
                                                                           9.99 and 999 settings for hours are not listed and should not be used.
                              0.1 hours to 99.9 hours  99.9        H
              Step 3          Desired Operation           Selection                         Remarks
                                                                           Use the m Time Setting Digital Switch to set the desired
                                                                           period of time. It is important to remember that the setting
         Set the precise period of time desired by using the m Time Setting Digital Switch.
                                                                           of the l Time Range Selector determines the units of time
                                                                           measurement as well as the implied decimal point location.  Circuit Breakers

             It is important to remember that the l Time Range Selector not only selects the time range but also infl uences the interpretation of the Digital Time Display.
             Changing the l Time Range Selector setting changes the units of time measurement (seconds, minutes, hours) as well as the decimal point location.