GT3F Series                                                                          Timers


        GT3F-2 Timing Diagrams GT3F-2 (8-pin)                                    GT3F-2E (11-pin)

     Switches & Pilot Lights  m n                      Delayed DPDT Output  n o p        (Transistor Input) n o p


                                                             (Contact Input)


                                                                       m
                                                                                                   m
                         l
                                                                                                             r
                                                                                 r
                                   p
                         k         o                      Reset        l         q    Reset        l         q
                       (-)            (+)                            (-)  k      s  (+)          (-)  k      s  (+)
                            j q                                           j                           j
                            POWER                                          POWER                       POWER
     Display Lights    Power  Terminal Number       Operation
                        Item
                                2 - 7
                              1 - 4
         8-Pin Type    Delayed   5 - 8  (NC)
                       Contact
                              1 - 3
                                    (NO)
                              6 - 8
                       Indicator  POWER
                       Set Time
                                                 T        Tr  T
                        Item  Terminal Number                 Operation
     Relays & Sockets  11-Pin Type  Reset   6 - 7 (11p)  ON or L
                                2 - 10
                       Power
                       Input
                              1 - 4
                                    (NC)
                       Delayed
                              8 - 11
                       Contact
                              1 - 3
                                    (NO)
                              9 - 11
                       Indicator
                       Set Time  POWER
                                             Tr  T             Ta                Ts  T

        When power is applied, the NO contact closes. When power is removed, the timing period begins. When time has elapsed, the NO contact opens. Optional reset
        input will return contacts to original state before time elapses.
             T = Set time
     Timers  Ta = Shorter than set time
             Ts = 1 Second
             Tr = Minimum Power Application Time
             GT3F-1: 1 Second




     Terminal Blocks   Power  6 - 7 (11p) 2 - 10  ON or L     Operation
                        Item
                             Terminal Number
                       Reset
                       Input
                              1 - 4
                       Delayed   8 - 11  (NC)
                       Contact  1 - 3
                              9 - 11  (NO)
                       Indicator  POWER
                       Set Time
                                            Tr   T             Ta                Ts  T