Timers                                                                 GT3 Series Instructions


                                               Inputs Instructions, continued


        For contact input, use gold-plated contacts to make sure that the residual voltage is less than 1V when the contacts are closed.

                       6  7                                                                                            Switches & Pilot Lights
                      5
          Reset Input  Start Input  Gate Input  3 4  8 9
                     2
                      1  11  10
                      Power
        For transistor input, use transistors with the following specifi cations; VCE = 40V, VCES = 1V or less, IC = 50 mA or more, and ICBO = 50μA or less. The resistance
        should be less than 1kΩ when the transistor is on. When the output transistor switches on, a signal is input to the timer.

                         6
                       5  7
           Reset Input  Start Input  Gate Input  3 4  8 9                                                              Display Lights
                      2
                       1  11  10
                       Power

        Inputs: GT3A-1, -2, -3

        Transistor output equipment such as proximity switches and photoelectric switches can input signals if they are voltage/current output type, with power voltage
        ranges from 18 to 30V and have1V. When the signal voltage switches from H to L, a signal is input to the timer
        Transistor Output                                                                                              Relays & Sockets
        Circuit

         Transistor
                   5, 6, 7
                   Input
                   Terminal
                  2
        Inputs: GT3A-4, -5, -6
                   The start input initiates a time-delay operation and controls
         Start Input                                   No-voltage contact inputs and NPN open collector transis-
                   output status.
                                                       tor inputs are applicable.                                      Timers
                   When the reset input is activated, the time is reset, and
         Reset Input
                   contacts return to original state.  24V DC, 1mA maximum
                   The time-delay operation is suspended while the gate input
         Gate Input                                    Input response time: 50msec maximum
                   is on (pause).                                                                                      Terminal Blocks































                                            USA: 800-262-IDEC          Canada: 888-317-IDEC                        841  Circuit Breakers