ABB  SWITCH-DISCONNECTORS – HIGH PERFORMANCE, COMPACT SOLUTION
                           ABB    S W I T C H - D I S C O N N E C T O R S  –  H I G H  P E R F OR M A NC E,  C OM P A C T  S OL UT I ON    11 11



          —
          Manual switch-disconnectors OT16...125, IEC

          Technical data


          Technical data according to IEC 60947-3
          Switch type                                        OT16F   OT25F   OT40F   OT63F  OT80F   OT100F  OT125F     01
          Rated insulation voltage and    Pollution degree 3  750 V  750 V   750 V   750 V   750 V   750 V   750 V
          rated operational voltage AC20/DC20
          Dielectric strength                    50 Hz        6 kV    6 kV    6 kV    6 kV    6 kV    6 kV    6 kV     02
                                                 1 min.
          Rated impulse withstand voltage                     8 kV    8 kV    8 kV    8 kV    8 kV    8 kV    8 kV
          Rated thermal current and rated  Ambient 40 °C  2)  In open air   25 A  32 A  40 A  63 A  80 A  115 A  125 A  03
          operational current AC20/DC20                                        Ambient 40 °C  2)  In enclosure  25 A  32 A  40 A  63 A  80 A  115 A  125 A
                                                      Ambient 60 °C   In enclosure  20 A  25 A  32 A  50 A  63 A  80 A  100 A
          ...with minimum conductor cross section  Cu        4 mm²   6 mm²  10 mm²  16 mm²  25 mm²  35 mm²  50 mm²     04
          Rated operational current,  AC-21A           up to 415 V  16 A  25 A  40 A  63 A    80 A   100 A   125 A
                                                 440...690 V  16 A    25 A    40 A    63 A    80 A   100 A   125 A
          Rated operational current,  AC-22A           up to 415 V  16 A  25 A  40 A  63 A    80 A   100 A   125 A
                                                 440...690 V  16 A    25 A    40 A    63 A    80 A   100 A   125 A
          Rated operational current,  AC-23A        up to 415 V  16 A  20 A   23 A    63 A    75 A    80 A    90 A
                                                 440 V        16 A    20 A    23 A    63 A    65 A    65 A    78 A
                                                 500 V        16 A    20 A    23 A    45 A    58 A    60 A    70 A
                                                 690 V        10 A    11 A    12 A    20 A    20 A    40 A    50 A
          Rated operational current /            24...48 V  1)  16 A/1  25 A/1  32 A/1  63 A/1  80 A/1  100 A/1  125 A/1
          poles in series, DC-21A                110 V       16 A/2  25 A/2  32 A/2  63 A/2  80 A/2  100 A/2  125 A/2
                                                 220 V       16 A/3  25 A/3  32 A/3  63 A/4  80 A/4  100 A/4  125 A/4
                                                 440 V       16 A/4  16 A/4  16 A/4  16 A/4  16 A/4     –       –
                                                 500 V       16 A/4  16 A/4  16 A/4  16 A/4  16 A/4     –       –
                                                 750 V       16 A/8  25 A/8  32 A/8     –       –       –       –
          Rated operational current /            24...48 V  1)  16 A/1  25 A/1  32 A/1  63 A/1  80 A/1  100 A/1  125 A/1
          poles in series, DC-22A                110 V       16 A/2  25 A/2  32 A/2  63 A/2  80 A/2  100 A/2  125 A/2
                                                 220 V       16 A/3  25 A/3  32 A/4  45 A/4  45 A/4  63 A/4  80 A/4
                                                 440 V       10 A/4  10 A/4  10 A/4  10 A/4  10 A/4     –       –
                                                 750 V       16 A/8  25 A/8  25 A/8     –       –       –       –
          Rated operational current /            24...48 V  1)  16 A/1  25 A/1  32 A/1  63 A/1  80 A/1  100 A/1  125 A/1
          poles in series, DC-23A                110 V       16 A/2  25 A/2  32 A/2  63 A/2  80 A/2  100 A/2  125 A/2
                                                 220 V       16 A/4  25 A/4  32 A/4  45 A/4  45 A/4  63 A/4  63 A/4
                                                 440 V       10 A/4  10 A/4  10 A/4  10 A/4  10 A/4     –       –
                                                 750 V       16 A/8  16 A/8  16 A/8     –       –       –       –
          Rated operational power, AC-23A        220...240 V  3 kW    4 kW   5.5 kW  11 kW   22 kW   22 kW   22 kW
          (These values are given for guidance   400...415 V  7.5 kW  9 kW   11 kW   22 kW   37 kW   37 kW   45 kW
          and may vary acc. to the motor         440...500 V  7.5 kW  9 kW   11 kW   22 kW   37 kW   37 kW   45 kW
          manufacturer)                          690 V       7.5 kW   9 kW   11 kW   15 kW  18.5 kW  37 kW   45 kW
          Rated breaking capacity, AC-23A        up to 415 V  128 A  160 A   184 A   360 A   640 A   640 A   720 A
                                                 440 V       128 A   160 A   184 A   360 A   448 A   520 A   624 A
                                                 500 V       128 A   160 A   184 A   360 A   464 A   480 A   560 A
                                                 690 V        80 A    88 A    96 A   160 A   160 A   320 A   400 A
          Rated breaking capacity/               24...48 V   64 A/1  100 A/1  128 A/1  180 A/1  252 A/1  400 A/1  500 A/1
          poles in series, DC-23A                110 V       64 A/2  100 A/2  128 A/2  180 A/2  252 A/2  400 A/2  500 A/2
                                                 220 V       64 A/3  100 A/4  128 A/4  180 A/4  180 A/4  252 A/4  252 A/4
                                                 440 V       40 A/4  40 A/4  40 A/4  40 A/4  40 A/4     –       –
                                                 750 V       64 A/8  64 A/8  64 A/8     –       –       –       –
          Rated conditional short-circuit current I q  I q 50kA, ≤415V   Î c  6.5 kA  6.5 kA  6.5 kA  13 kA  13 kA  16.5 kA  16.5 kA
          (r.m.s.) and corresponding max. Allowed  Max. OFA_fuse size  gG/aM  40 A/32 A  40 A/32 A  40 A/32 A  100 A/80 A  100 A/80 A 125 A/125 A 125 A/125 A
          cut-off current Î c of fuse. The cut-off   I q 100kA, 500V   Î c  –  –  –  17 kA   17 kA      –       –
          current Î c referes to values listed by fuse  Max. OFA_fuse size  gG/aM  –  –  –  100 A/80 A  100 A/80 A  –  –
          manufacturers (single phase test acc. To   I q 10kA, 690V  –  –       –       –       –    8.2 kA  8.2 kA
          IEC60269)              Max. OFA_fuse size   Î c       –       –       –       –       – 125 A/100 A 125 A/100 A
                                                 gG/aM
                                 I q 50kA, 690V   Î c         4 kA    4 kA    4 kA   11 kA   11 kA   10 kA   10 kA
                                 Max. OFA_fuse size  gG/aM  25 A/16 A  25 A/16 A  25 A/16 A  80 A/63 A  80 A/63 A  63 A/63 A  63 A/63 A
          Rated short-time withstand current  r.m.s. -value   I cw  690 V, 1 s    0.5 kA  0.5 kA  0.5 kA  1.5 kA  1.5 kA  2.5 kA  2.5 kA
          Rated short circuit making capacity  Peak value     I cm  690 V/500 V  0.71 kA  0.71 kA  0.71 kA  2.1 kA  2.1 kA  3.6 kA  3.6 kA
          Rated capacitor power (the capacitor   400...415 V  6.5 kVAr  10 kVAr  15 kVAr  25 kVAr  30 kVAr  40 kVAr  50 kVAr
          ratings are limited by the fuse link.)
          Power loss/pole        At rated operational current  0.3 W  0.6 W  1.6 W   2.8 W   4.5 W   4.0 W   6.3 W
          Mechanical endurance   Divide by two for operation   20 000 Oper. 20 000 Oper. 20 000 Oper. 20 000 Oper. 20 000 Oper. 20 000 Oper. 20 000 Oper.
                                 cycles
          Weight without accessories  3-pole                 0.11 kg  0.11 kg  0.11 kg  0.27 kg  0.27 kg  0.36 kg  0.36 kg
                                 4-pole                      0.15 kg  0.15 kg  0.15 kg  0.35 kg  0.35 kg  0.50 kg  0.50 kg
          Cable size             Cu-wire size suitable    0.75...10 mm² 0.75...10 mm² 0.75...10 mm² 1.5...35 mm² 1.5...35 mm²  10...70 mm²  10...70 mm²
                                 for terminal clamps       18-8 AWG  18-8 AWG  18-8 AWG  14-4 AWG  14-4 AWG  8-00 AWG  8-00 AWG
          Terminal tightening torque  Counter torque required  0.8 Nm  0.8 Nm  0.8 Nm  2 Nm  2 Nm    6 Nm    6 Nm
          Operating torque       3-pole switch-disconnector   1 Nm    1 Nm   1 Nm   1.2 Nm  1.2 Nm   2 Nm    2 Nm
          1)  Below 48 V, two poles in parallel up to OT80 are recommended particularly in polluted atmosphere.
          2)  Acc. to IEC 60947-1, § 6.1.1.