9/4              SACE EMA X 2 LOW VOLTAGE AIR CIRCUIT-BRE AKERS



          —

          Reading information


          Circuit-breakers

















                           Key                                         Q/1...Q/25   = Auxiliary contacts of circuit- breaker
                           *         = See the note indicated by the letter  Q/26...Q/27  = Auxiliary open/close contacts used
                           A1        = Applications located on the mobile          internally by the trip unit
                                       part of the circuit-breaker     RC        = RC (residual current) protection
                           A3        = Applications located on the fixed           sensor
                                       part of the circuit-breaker     RT1…RT3    = Temperature sensors
                           A4        = Indicative devices and connections   RTC EKIP    = Auxiliary ready to close contact of
                                       for control and signalling, outside         circuit-breaker, used internally by
                                       the circuit-breaker                         the trip unit
                           BUS1      = Serial interface with external bus  RTC    = Contact for signalling circuit-
                           D         = Electronic time-lag device of YU            breaker is ready to close
                                       undervoltage coil, outside the    S33M/1…2   = Limit contacts of spring loading
                                       circuit-breaker                             motor
                           F1        = Time-delayed trip fuse          S43       = Switch for presetting remote/local
                           GZi(DBi)    = Zone selectivity input for G              control
                                       protection or input in “reverse” di-  S51    = Trip signalling contact
                                       rection for D protection        S75E/1…4   = Contacts for signalling circuit-
                           GZo(DBo)   = Zone selectivity output for G              breaker in racked-out position
                                       protection or output in “reverse”           (provided only with withdrawable
                                       direction for D protection                  version)
                           I O1…32    = Programmable digital inputs of the   S75I/1…5    = Contacts for signalling circuit-
                                       EKIP protection trip unit                   breaker in racked-in position
                           K51       = Electronic overcurrent protection           (provided only with withdrawable
                                       trip unit of the types: EKIP DIP,           version)
                                       EKIP TOUCH, EKIP LCD,           S75T/1…2   = Contact for signalling circuit-
                                       EKIP HI-TOUCH , EKIP HI-LCD,                breaker in test position (provided
                                       EKIP G TOUCH, EKIP G LCD,                   only with withdrawable version)
                                       EKIP G HI-TOUCH , EKIP G HI-LCD  SC       = Pushbutton or contact for closing
                           K51/COM    = Communication module                       the circuit-breaker
                           K51/MEAS   = Measurement module             SO        = Pushbutton or contact for
                           K51/SIGN   = Signalling module                          immediate opening of the circuit-
                           K51/SUPPLY = Optional auxiliary supply module           breaker
                                       (110-220VAC/DC and 24-48VDC)    SO1       = Pushbutton or contact for opening
                           K51/SYNC   = Synchronization module                     the circuit-breaker with  time-
                           K51/YC    = Closing control from the EKIP               delayed trip
                                       protection trip unit            SR        = Pushbutton or contact for
                           K51/YO    = Opening control from the EKIP               electrical resetting of S51trip
                                       protection trip unit                        contact
                           M         = Motor for loading closing springs  SZi(DFi)    = Input for zone selectivity for S and I
                           O 01...32    = Programmable signalling contacts         protection or input in “direct” di-
                                       of the EKIP protection trip unit            rection for D protection
                           O SC      = EKIP protection trip unit contact   SZo(DFo)    = Output for zone selectivity for S
                                       for synchronism control                     and I protection or output in “di-
                           Q         = Circuit-breaker                             rect” direction for D protection