3/6              SACE EMA X 2 LOW VOLTAGE AIR CIRCUIT-BRE AKERS



          —

          New digital experience


          Packages









                           Each package includes a set of protection func-
                           tions or measurements that can be enabled in the
                           trip unit.
                           Six packages relate to protection functions: Volt-
                           age Protections, Frequency Protections, Power
                           Protections, Advanced Voltage Protections, RO-  Advanced Voltage Protections
                           COF Protections and Adaptive Protections.   Set of protections included: S(V) - Voltage con-
                                                                       trolled overcurrent, S(V)2 - 2nd Voltage controlled
                                                                       overcurrent, R - Residual voltage.
                                                                       How to order: via ABB Ability Marketplace™ or tra-
                                                                       ditional ordering channels.


                           Voltage Protections
                           Set of protections included: UV - Undervoltage,
                           OV - Overvoltage, UV2 - 2nd Undervoltage, OV2 -
                           2nd Overvoltage, PS - Phase Sequence, VU - Volt-
                           age unbalance.                              ROCOF Protections
                           How to order: via ABB Ability Marketplace™ or tra-  Set of protections included: ROCOF - Rate of
                           ditional ordering channels.                 change of frequency.
                                                                       How to order: via ABB Ability Marketplace™ or tra-
                                                                       ditional ordering channels.


                           Frequency Protections
                           Set of protections included: UF - Underfrequency,   Adaptive Protections
                           OF - Overfrequency ,  UF2 - 2nd Underfrequency,   Set of protections included: Dual Setting - Set A-B.
                           OF2 - 2nd Overfrequency.                    How to order: via ABB Ability Marketplace™ or tra-
                           How to order: via ABB Ability Marketplace™ or tra-  ditional ordering channels.
                           ditional ordering channels.








                           Power Protections
                           Set of protections included: RP - Reverse active
                           power, CosΦ - Power factor, D - Directional over-
                           current, RQ - Loss of field or reverse reactive
                           power, OQ - Reactive overpower, OP - Active over
                           power, UP - Active underpower, RQ - 2nd Loss of
                           field or Reverse reactive power.
                           How to order: via ABB Ability Marketplace™ or tra-
                           ditional ordering channels.