Page 34 - Sace Emax 2 Catalogue
P. 34

3/10             SACE EMA X 2 LOW VOLTAGE AIR CIRCUIT-BRE AKERS



          —

          New digital experience


          Solutions










                                                      Functions included         Hardware accessories
                           PACKAGES
                           Voltage Protections        UV - Undervoltage          -
                                                      OV - Overvoltage
                                                      UV2 – 2nd Undervoltage
                                                      OV2 – 2nd Overvoltage
                                                      PS – Phase sequence
                                                      VU – Voltage unbalance
                           Frequency Protections      UF - Underfrequency        -
                                                      OF - Overfrequency
                                                      UF2 – 2nd Underfrequency
                                                      OF2 - 2nd Overfrequency
                           Power Protections          RP – Reverse active power  -
                                                      Cos Φ- Power factor
                                                      D – Directional current
                                                      RQ – Loss of field or Reverse reactive
                                                      power
                                                      OQ – Reactive overpower
                                                      OP – Active overpower
                                                      UP – Active underpower
                                                      2RQ – 2nd Loss of field or Reverse
                                                      reactive power
                           Advanced Voltage Protections   S(V) – Voltage controlled overcurrent  -
                                                      S(V)2 – 2nd Voltage controlled
                                                      overcurrent
                                                      R – Residual voltage
                           ROCOF Protections          ROCOF                      -
                           Adaptive Protections       Dual setting               Ekip Signalling
                           Measuring Package          Phase-to-phase voltage     -
                                                      Phase-to-neutral voltage
                                                      Phase sequence
                                                      Frequency
                                                      Active power
                                                      Reactive power
                                                      Apparent power
                                                      Power factor
                                                      Peak factor
                                                      Active energy
                                                      Reactive energy
                                                      Apparent energy
                           Data Logger                Currents                   -
                                                      Voltages
                                                      Sampling rate
                                                      Maximum recording duration
                                                      Recording stop delay
                                                      Number of registers
                           Network Analyzer           Hourly average voltage value  -
                                                      Short voltage interruptions
                                                      Short voltage spikes
                                                      Slow voltage sags and swells
                                                      Voltage unbalance
                                                      Harmonic analysis
   29   30   31   32   33   34   35   36   37   38   39