Page 31 - Sace Emax 2 Catalogue
P. 31

PROTECTION TRIP UNITS                                                             3/7



















                                                                                                                       03
                           Three packages relate to measurements and di-
                           agnostics: Measuring Package, Data Logger and
                           Network Analyzer.


                                                                       Network Analyzer
                                                                       To monitor the power quality of the network
                                                                       through: Harmonic analysis, Hourly average volt-
                                                                       age value, Short voltage interruption, Short volt-
                           Measuring Package
                           To monitor the plant through several measure-  age spikes, Slow-voltage sags and swells, Voltage
                           ments: Phase-to-phase voltage, Phase-to-neutral   unbalance.
                           voltage, Phase sequence, Frequency, Active   How to order: via ABB Ability Marketplace™ or tra-
                           power, Reactive power, Apparent power, Power   ditional ordering channels.
                           factor, Peak factor, Active energy, Reactive en-
                           ergy, Apparent energy.                      When a package is purchased via ABB Ability Mar-
                                                                       ketplace , it must be activated through:
                                                                             TM
                           How to order: via ABB Ability Marketplace™ or tra-  •  Ekip Connect 3 installed on a PC using Ekip T&P
                           ditional ordering channels.
                                                                        to scan the trip unit
                                                                       •  EPiC app mobile installed on a mobile device, by
                                                                        directly using the embedded Bluetooth connec-
                                                                        tion available in the new Ekip trip units.


                           Data Logger
                           To record data about events in the plant: Cur-
                           rents, Voltages, Sampling rate, Maximum record-
                           ing duration, Recording stop delay, Number of
                           registers.
                           How to order: via ABB Ability Marketplace™ or tra-
                           ditional ordering channels.

                           Thanks to the maximum flexibility guaranteed by these packages, the new Ekip trip units are now com-
                           pletely customizable. Depending on the specific trip unit version, different packages are available by
                           default, but all of them can be added to the trip unit.

                           Default functionalities and upgradability of the trip units:





                        Standard   Standard  Measuring  Voltage   Frequency   Power  Adaptive   Data   Network   Advanced   ROCOF
                       Protection Measures  Package  Protections Protections Protections Protections  Logger  Analyzer  Voltage   Protections
                                                                                                Protections
          Ekip Touch                      ↑ ↑     ↑ ↑     ↑ ↑     ↑ ↑     ↑ ↑     ↑ ↑     ↑ ↑     ↑ ↑     ↑ ↑
          Ekip G Touch                            ↑ ↑     ↑ ↑     ↑ ↑     ↑ ↑             ↑ ↑     ↑ ↑     ↑ ↑
          Ekip Hi-Touch                                           ↑ ↑                             ↑ ↑     ↑ ↑
          Ekip G Hi-Touch
            Available by default
          ↑  ↑ Upgradable

          ↑ ↑ Some elements of the package are already provided by default. It is possible to upgrade the trip unit to achieve the complete package.