            S33 M/2: springs charged  The S33 M/2 contact signals the state of the closing springs of the circuit-breaker control (charged or
                   signalling contact discharged).
                                    It is available in two types:
                                     •  standard contact
                                     •  contact for digital signals
                                           NOTE: the S33_M/2 contact is always included in the gearmotor for automatic charging of
                                               the springs in the standard version. The version for digital signals must be requested
                                           with the order for the motor.


                                                       35

                                                       36

                                                       38

                                                      S33

                                    S33 M/2 for E1.2


                                                       35

                                                       36
                                                       38

                                                      S33


                                    S33 M/2 for E2.2 - E4.2 - E6.2
                                    The following table provides information on the electrical characteristics:
                                     Characteristics               Standard                  Digital signals
                                                         24V       -                         0.1 A
                                                  DC     125V      0.5A @ 0ms / 0.3A @ 10ms  -
                                                         250V      0.3A @ 0ms / 0.15A @ 10ms  -
                                                                   3A cos  φ 0.3             -
                                     Breaking            250V      5A cos  φ 0.7             -
                                     capacity
                                                                   5A cos  φ 1               -
                                                  AC
                                                                   3A cos  φ 1               -
                                                         400V      2A cos  φ 0.7             -
                                                                   1A cos  φ 0.3             -
                                     Minimum load                  100mA @ 24V               1mA @ 5V

                                    S33/M2: Connections
                                    More details are available in the website http://www.abb.com/abblibrary/DownloadCenter/, which also
                                    includes the entire circuit diagram 1SDM000091r0001.
                                    Information on the assembly is available on the website http://www.abb.com/abblibrary/DownloadCenter/,
                                    in particular for E1.2 in the kit sheet  1SDH000999r0609 and for E2.2-E4.2-E6.2 in the kit sheet
                                    1SDH001000r0609.