7/56             SACE TMAX XT LOW VOLTAGE MOLDED CASE CIRCUIT-BREAKERS



          —

          Residual current protection













                           The fixed version of the RC Sel residual current release can be easily converted:
                           •  into a plug-in type of release:
                               - by ordering the kit for converting the residual current release from the fixed to the plug-in version
                           •  into a withdrawable type of release:
                               - by ordering the kit for converting the residual current release from the plug-in to the withdrawable
                              version. This kit contains the shunt opening release of the withdrawable residual current device to
                              replace the shunt opening release supplied with the fixed version. The shunt opening release of the
                              withdrawable residual current device contains both the connector for the moving part and the
                              connector for the fixed part.
                           With the RC Sel residual current release for the XT2-XT4, it is possible to use the same terminals for the
                           fixed circuit-breaker and for the fixed parts of the plug-in and withdrawable circuit-breakers.
                           With the withdrawable and plug-in versions, frame 160A with RC can be used up to a maximum current of
                           135A, whereas frame 250A can be used up to 210A.

                           RC Sel current releases (type A) for XT5

                                                                                                      Test pushbutton


                           Current setting

                                                                                                     Reset pushbutton
                           Power-on LED


                           Alarm and prealarm
                           signal LED
                                                                                                   Disconnection device
                                                                                                     for Insulation test

                           Time of non trip setting





                           The fixed version of the RC Sel residual current release can easily be converted:
                           •  into a plug-in type of release:
                               - by ordering the kit for converting the residual current release from the fixed to the plug-in version
                           •  into a withdrawable type of release:
                               - by ordering the kit for converting the residual current release from the plug-in to the withdrawable
                              version.
                           With the RC Sel residual current release for the XT5, it is possible to use the same terminals for the fixed
                           circuit-breaker and for the fixed parts of the plug-in and withdrawable circuit-breakers.
                           RC Sel for XT5 is always a four poles version that can be mounted also on a three-pole circuit breakers
                           using the dedicated cover supplied in the RC kit.