Surge Arresters – Type 2

        952 328   DG M TT 150 FM
        952 315   DG M TT 275 FM
        952 325   DG M TT 320 FM  DEHNguard M TT ... FM
        952 316   DG M TT 385 FM
                         Modular surge arrester for use in TT and TN-S systems (3+1 configuration); with floating remote signalling contact.
        952 328   4013364133242  04 01 02 01   390 g
              350,40 €
        952 315   4013364108486  04 01 02 01   415 g
              328,40 €                                  TT 150 FM     TT 275 FM    TT 320 FM     TT 385 FM
        952 325   4013364126800  04 01 02 01   425 g   Type DG M ...
              350,50 €
        952 316   4013364119406  04 01 02 01   436 g
              350,40 €
                          Part No.                      952 328       952 315      952 325       952 316
                          SPD according to EN 61643-11 / IEC 61643-11  type 2 / class II   type 2 / class II   type 2 / class II   type 2 / class II
                          Max. continuous operating voltage (a.c.) [L-N]  (UC) 150 V (50 / 60 Hz)   275 V (50 / 60 Hz)   320 V (50 / 60 Hz)   385 V (50 / 60 Hz)
                          Nominal discharge current (8/20 µs)  (In)  15 kA  20 kA  20 kA         20 kA
                          Max. discharge current (8/20 µs)  (Imax)  40 kA  40 kA   40 kA         40 kA
                          Lightning impulse current (10/350 µs) [N-PE]  (Iimp)  12 kA  12 kA  12 kA  12 kA
                          Voltage protection level [L-N]/[N-PE]  (UP)  ≤ 0.7 / ≤ 1.5 kV  ≤ 1.5 / ≤ 1.5 kV  ≤ 1.5 / ≤ 1.5 kV  ≤ 1.75 / ≤ 1.5 kV
                          Max. mains-side overcurrent protection  125 A gG  125 A gG  125 A gG   125 A gG
                          Approvals                     UL            KEMA, VDE, UL   KEMA       KEMA, UL
                          Type of remote signalling contact  changeover contact   changeover contact   changeover contact   changeover contact
                         DEHNguard M TN ...
        952 201   DG M TN 150
        952 200   DG M TN 275
                         Modular surge arrester for use in single-phase TN systems (2+0 configuration).
        952 201   4013364123915  04 01 02 01   211 g
              149,00 €
        952 200   4013364108394  04 01 02 01   229 g
              133,60 €    Type DG M ...                 TN 150                     TN 275
                          Part No.                      952 201                    952 200
                          SPD according to EN 61643-11 / IEC 61643-11  type 2 / class II   type 2 / class II
                          Max. continuous operating voltage (a.c.)  (UC)  150 V (50 / 60 Hz)   275 V (50 / 60 Hz)
                          Nominal discharge current (8/20 µs)  (In)  15 kA         20 kA
                          Max. discharge current (8/20 µs)  (Imax)  40 kA          40 kA
                          Voltage protection level [L-PE]/[N-PE]  (UP)  ≤ 0.7 / ≤ 0.7 kV  ≤ 1.5 / ≤ 1.5 kV
                          Max. mains-side overcurrent protection  125 A gG         125 A gG
                          Approvals                     KEMA, UL                   KEMA, VDE, UL
                         DEHNguard M TN ... FM
        952 206   DG M TN 150 FM
        952 205   DG M TN 275 FM
                         Modular surge arrester for use in single-phase TN systems (2+0 configuration); with floating remote signalling contact.
        952 206   4013364123922  04 01 02 01   217 g
              175,30 €
        952 205   4013364108400  04 01 02 01   232 g
              160,00 €    Type DG M ...                 TN 150 FM                  TN 275 FM
                          Part No.                      952 206                    952 205
                          SPD according to EN 61643-11 / IEC 61643-11  type 2 / class II   type 2 / class II
                          Max. continuous operating voltage (a.c.)  (UC)  150 V (50 / 60 Hz)   275 V (50 / 60 Hz)
                          Nominal discharge current (8/20 µs)  (In)  15 kA         20 kA
                          Max. discharge current (8/20 µs)  (Imax)  40 kA          40 kA
                          Voltage protection level [L-PE]/[N-PE]  (UP)  ≤ 0.7 / ≤ 0.7 kV  ≤ 1.5 / ≤ 1.5  kV
                          Max. mains-side overcurrent protection  125 A gG         125 A gG
                          Approvals                     KEMA, UL                   KEMA, VDE, UL
                          Type of remote signalling contact  changeover contact    changeover contact
                         DEHNguard M H TT 2P ... (FM)
        952 181   DG M H TT 2P 275
        952 185   DG M H TT 2P 275 FM
                         Modular surge arrester with a high total discharge capacity in the N-PE path for TT and TN systems (1+1 configuration); meets the increased
                         safety requirements by higher discharge capability; with floating remote signalling contact.
        952 181   4013364318175  04 01 02 01   228 g
              160,70 €
        952 185   4013364318151  04 01 02 01   228 g
              173,90 €
                          Type DG M ...                 H TT 2P 275                H TT 2P 275 FM
    Surge Arresters – Type 2  SPD according to EN 61643-11 / IEC 61643-11  type 2 / class II   type 2 / class II
                                                                                   952 185
                          Part No.
                                                        952 181
                                                                                   275 V (50 / 60 Hz)
                          Max. continuous operating voltage (a.c.) [L-N]  (UC) 275 V (50 / 60 Hz)
                                                                                   20 kA
                          Nominal discharge current (8/20 µs) [L-N]  (In)
                                                        20 kA
                          Nominal discharge current (8/20 µs) [N-PE]  (In)
                          Max. discharge current (8/20 µs) [L-N]  (Imax)  80 kA    80 kA
                                                        40 kA
                                                                                   40 kA
                          Max. discharge current (8/20 µs) [N-PE]  (Imax)  120 kA  120 kA
                          Lightning impulse current (10/350 µs) [N-PE]  (Iimp)  40 kA  40 kA
                          Voltage protection level [L-N]/[N-PE]  (UP)  ≤ 1.5 / ≤ 1.5 kV  ≤ 1.5 / ≤ 1.5  kV
                          Max. mains-side overcurrent protection  125 A gG         125 A gG
                          Approvals                     KEMA                       KEMA
                          Type of remote signalling contact  —                     changeover contact
        952 110   DG M TT 2P 275
        952 130   DG M TT 2P 320
        952 111   DG M TT 2P 385  DEHNguard M TT 2P ...
                         Modular surge arrester for use in single-phase TT and TN systems (1+1 configuration).
        952 110   4013364108417  04 01 02 01   242 g
              155,30 €
        952 130   4013364128521  04 01 02 01   247 g
              162,90 €
        952 111   4013364119420  04 01 02 01   232 g
              162,90 €
                          Type DG M ...                 TT 2P 275     TT 2P 320    TT 2P 385
                          Part No.                      952 110       952 130      952 111
                          SPD according to EN 61643-11 / IEC 61643-11  type 2 / class II   type 2 / class II   type 2 / class II
                          Max. continuous operating voltage (a.c.) [L-N]  (UC) 275 V (50 / 60 Hz)   320 V (50 / 60 Hz)   385 V (50 / 60 Hz)
                          Nominal discharge current (8/20 µs)  (In)  20 kA  20 kA  20 kA
                          Max. discharge current (8/20 µs)  (Imax)  40 kA  40 kA   40 kA
                          Lightning impulse current (10/350 µs) [N-PE]  (Iimp)  12 kA  12 kA  12 kA
                          Voltage protection level [L-N]/[N-PE]  (UP)  ≤ 1.5 / ≤ 1.5 kV  ≤ 1.5 / ≤ 1.5 kV  ≤ 1.75 / ≤ 1.5 kV
                          Max. mains-side overcurrent protection  125 A gG  125 A gG  125 A gG
                          Approvals                     KEMA, VDE, UL   KEMA       KEMA