Page 69 - Surge-Protection-E_0.pdf
P. 69
Surge Arresters – Type 2
DEHNguard S
• Multi-purpose surge arrester consisting of a base part and a
plug-in protection module
• High discharge capacity due to heavy-duty zinc oxide varistor
• High reliability due to "Thermo Dynamic Control" SPD
monitoring device
• Energy coordination with other arresters of the Red/Line
product family
• Operating state / fault indication by green / red indicator flag
in the inspection window
• Narrow (modular) design acc. to DIN 43880
• Multifunctional terminals for connecting conductors and
busbars
• Easy replacement of protection modules due to module
locking system with module release button For protecting low-voltage consumer installations against surges. For installation
• Vibration and shock-tested according to EN 60068-2 in conformity with the lightning protection zone concept at the boundaries from
0B – 1 and higher.
DEHNguard S ...: Pluggable surge arrester consisting of a base part and a plug-in protection module
DEHNguard S ... FM: With remote signalling contact for monitoring device (floating changeover contact)
The universal features characterise the single-pole devices of the Every base part and protection module is mechanically coded to guard
DEHNguard S product family. Whether as a single device or in combination against installing an incorrect module.
with other devices – DEHNguard S surge arresters always provide ade- As with all DEHNguard surge arresters, the user of DEHNguard S can rely
quate protection. The modern Red/Line family design and its universal on the dual "Thermo Dynamic Control" SPD monitoring device which
features ensure safety and easy application for the user. The module re- ensures a maximum degree of safety, even under harsh environmental
lease button and the approved "Thermo Dynamic Control" SPD monitor- conditions. The green and red indicator flags shows the operating state of
ing device with dual tripping performance characterise the devices of the DEHNguard S surge arresters. Apart from this standard visual indication,
DEHNguard S series. DEHNguard S ... FM features a three-pole remote signalling terminal. As
Decades of experience in the world market of surge arresters has further the remote signalling contact is designed as a floating changeover con-
improved the latest DEHNguard generation compared to the previous tact, the remote signal can, depending on the circuit concept, be used as
devices. a make or break contact. The multifunctional terminals of DEHNguard S
The unique module locking system fixes the protection module to the base surge arresters are suitable for connecting conductors and busbars, allow-
part. Neither vibration during transport nor the enormous forces of dis- ing easy wiring with other DIN rail mounted devices. Thus, a wide range
charge can loosen this connection. Nevertheless, the modules can be of applications can be easily connected in series according to IEC 60364-
easily replaced without tools by simply pressing the easy-to-use module 5-53 for optimal protection.
release button of the protection modules.
DEHNguard S ... 952 078 952 071 952 072 952 070 952 073 DG S 48 DG S 75 DG S 150 DG S 275 DG S 320
952 075 952 074 DG S 385 DG S 440
952 076 DG S 600
Pluggable single-pole surge arrester consisting of a base part and a plug-in protection module.
952 078 4013364119468 04 01 02 02 109 g
82,20 €
952 071 952 072 4013364109834 04 01 02 02 107 g 109 g
82,20 €
4013364109858 04 01 02 02
General technical data: 952 070 952 073 952 074 82,20 € 4013364108493 04 01 02 02 130 g 119 g 123 g
74,50 €
4013364109872 04 01 02 02
82,20 €
4013364108516 04 01 02 02
952 075 82,20 € 4013364109896 04 01 02 02 142 g
952 076 82,20 € 4013364109919 04 01 02 02 136 g
SPD according to EN 61643-11 / IEC 61643-11 type 2 / class II
82,20 €
Type DG S ... 48 75 150 275
Part No. 952 078 952 071 952 072 952 070 Surge Arresters – Type 2
Max. continuous operating voltage (a.c.) (UC) 48 V (50 / 60 Hz) 75 V (50 / 60 Hz) 150 V (50 / 60 Hz) 275 V (50 / 60 Hz)
Nominal discharge current (8/20 µs) (In) 7.5 kA 10 kA 15 kA 20 kA
Max. discharge current (8/20 µs) (Imax) 25 kA 40 kA 40 kA 40 kA
Voltage protection level (UP) ≤ 0.33 kV ≤ 0.4 kV ≤ 0.7 kV ≤ 1.5 kV
Max. mains-side overcurrent protection 125 A gG 125 A gG 125 A gG 125 A gG
Approvals — KEMA, VDE, UL, CSA KEMA, VDE, UL, CSA KEMA, VDE, UL,CSA
Type DG S ... 320 385 440 600
Part No. 952 073 952 074 952 075 952 076
Max. continuous operating voltage (a.c.) (UC) 320 V (50 / 60 Hz) 385 V (50 / 60 Hz) 440 V (50 / 60 Hz) 600 V (50 / 60 Hz)
Nominal discharge current (8/20 µs) (In) 20 kA 20 kA 20 kA 15 kA
Max. discharge current (8/20 µs) (Imax) 40 kA 40 kA 40 kA 30 kA
Voltage protection level (UP) ≤ 1.5 kV ≤ 1.75 kV ≤ 2 kV ≤ 2.5 kV
Max. mains-side overcurrent protection 125 A gG 125 A gG 125 A gG 100 A gG
Approvals KEMA, VDE, UL, CSA KEMA, VDE, UL, CSA KEMA, VDE, UL, CSA KEMA, VDE, UL, CSA
Valid as of August 1, 2020 You will find detailed product information on our website 65