Page 97 - Surge-Protection-E_0.pdf
P. 97
Surge Arresters – Type 2
DEHNguard PCB
• Base for DEHNguard protection modules to be mounted on
and integrated in PCBs
• Optimal integration of a type 2 arrester in devices
• Easy and flexible use for all circuit configurations
• Proven DEHNguard modules ensure high performance
• Coded base and protection module guard against installing
an incorrect module
• Version with and without remote signalling contact for the
monitoring device
• Versions for maximum requirements on clearances and
creepage distances
• Versions for other DEHNguard protection modules available
on request
For integrating a type 2 arrester on the printed circuit board of a device to provide
surge protection. For installation in conformity with the lightning protection zone
concept at the boundaries from 0B– 1 and higher.
DEHNguard PCB ...: Base for mounting arresters on printed circuit boards
DEHNguard PCB ... FM: With remote signalling contact for monitoring device (floating changeover contact)
DEHNguard PCB … I … FM: With increased clearances and creepage distances between the power and remote signalling contact
The single-pole DEHNguard PCB ... (FM) base is specially designed for use PCB (FM). Neither vibration in the application environment nor the dy-
on printed circuit boards (PCBs). Thus, surge protection can be taken into namic forces of discharge can loosen the protection modules. Nevertheless,
account at an early stage of development of the PCB and can be optimal- they can be easily replaced without tools by simply pressing the easy-to-
ly integrated in the overall product. This single-pole version can be used use module release button of the protection modules.
for all system configurations. Fault-resistant Y circuits for PV systems or Each DEHNguard PCB (FM) base and each protection module is mechan-
3+1 configurations for a.c. systems can be easily implemented. ically coded to guard against installing an incorrect module.
Thanks to the ideal positioning of the SPD on the device, an optimal volt- The DG PCB … I … FM versions ensure increased distances between the
age protection level is achieved for the electronics of the PCB since there power and remote signalling contact since special applications place in-
is no cable length between the SPD and the device to be protected creased requirements on clearances and creepage distances between
through which additional surges may be injected (in typical applications). these circuits. Details can be found in the drilling scheme of the installa-
The design of the PCB also allows series connection according to IEC tion instructions which can be downloaded free of charge at www.
60364-5-53. dehn-international.com.
Various device features show that reliable surge protection and equip- The ...FM version of DG PCB... features a three-pole remote signalling
ment reliability are a top priority of the modular DEHNguard. The applica- contact. As the remote signalling contact is designed as a floating change-
tion-oriented product designation, which makes it considerably easier to over contact, the remote signal can, depending on the circuit concept, be
assign the protection modules to the relevant DG PCB base part, and the used as a make or break contact.
unique module locking system reflect the high safety requirements. The
module locking system firmly fixes the protection modules to DEHNguard
DEHNguard PCB PV SCI ... 952 653 952 651 952 654 DG PCB PV SCI 300
DG PCB PV SCI 500
DG PCB PV SCI 600
Single-pole base for DEHNguard modules to be mounted on the PCBs of devices.
952 653 4013364150713 04 01 02 12 18 g Surge Arresters – Type 2
5,90 €
952 651 952 654 4013364146310 04 01 02 12 18 g 18 g
5,90 €
4013364149878 04 01 02 12
Type DG PCB ... PV SCI 300 PV SCI 500 PV SCI 600 5,90 €
Part No. 952 653 952 651 952 654
DG MOD PV SCI 300 DG MOD PV SCI 500 DG MOD PV SCI 600
Associated protection module
(Part No. 952 053) (Part No. 952 051) (Part No. 952 054)
Max. continuous operating voltage (d.c.) (module) 300 V 500 V 600 V
For mounting on directly soldered into PCB directly soldered into PCB directly soldered into PCB
IP 20 (protection module IP 20 (protection module IP 20 (protection module
Degree of protection
plugged in) plugged in) plugged in)
Valid as of August 1, 2020 You will find detailed product information on our website 93